MAINTENANCE
| ERROR MESSAGE |
| POSSIBLE SOLUTION | ||||||
| AND DESCRIPTION |
| |||||||
|
|
|
|
|
| ||||
|
|
|
|
|
| ||||
Port |
| CP | Missing | B u t | Check CP slot; reseat CP; change | ||||
“Administered: | (Other | than | CP; or | remove | C P f r o m | ||||
CPU/Memory) Translated port CP | translations. If CP does not pass | ||||||||
that CPU cannot access. |
| ||||||||
|
| ||||||||
Port CP Out Of Service: (Other | If the CP has not been removed | ||||||||
than | CPU/Memory) | Message | and the problem persists, check | ||||||
occurs when a CP is removed | or replace the port CP. |
| |||||||
from a cabinet. Error removed |
|
|
|
| |||||
when the CP passes |
|
|
|
| |||||
|
| ||||||||
Port CP ROM Checksum Failure: | Try reseating the CP. If this error | ||||||||
The port CP has found that the | happens again, then replace the | ||||||||
checksum on its firmware is bad. | C P . |
|
|
| |||||
|
|
|
|
| |||||
Port | Buffer | Full: | (STARLAN | If the reset is not successful, | |||||
Interface CP) This error resets the | reseat CP. If the reseat fails, | ||||||||
C P . |
|
|
|
|
| replace | the | CP. |
|
|
|
|
| ||||||
Port Fault: For an auxiliary trunk, | C h e c k | wiring of | external | ||||||
this message is logged when a | equipment (see Figure | ||||||||
ground is expected from external |
|
|
|
| |||||
equipment and is not detected. |
|
|
|
| |||||
|
|
|
|
| |||||
Port | Queue | Full: | (STARLAN | If the reset is not successful, | |||||
Interface CP) This error resets the | reseat CP. If the reseat fails, | ||||||||
CP . |
|
|
|
|
| replace the CP. |
| ||
|
|
| |||||||
Program | Logic Inconsistent: | Reseat CP. If problem persists, | |||||||
( O t h e r t h a n CPU/Memory) | replace | it. |
|
| |||||
Possible | hardware problem on |
|
|
|
| ||||
port | CP. |
|
|
|
|
|
|
|
|
|
|
|
| ||||||
RAM Test Failed: CPU/Memory | Check | CPU/Memory | CP. | ||||||
CP has failed the RAM test. |
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|