INSTALLATION
INSTALL EQUIPMENT ROOM STATION CABLING
System 25 is connected to the building (station) wiring in two stages. First, the building wiring is connected to the Station Interconnect Panel (SIP). Then, the octopus cables from the back of the cabinets are connected to the SIP.
Accurate documentation during installation is essential to the performance and maintenance of System 25 and will make initialization and administration much easier to perform. The Voice and Data Station Records Form (Figure
As the octopus cables are connected to the SIP, the port assignment for each station should be added to the Voice and Data Station Records Form. Port assignments are identified by cabinet number (1, 2, or 3), circuit pack slot number (1 through 12), and port number (1 through 8). For example