MAINTENANCE

 

ERROR MESSAGE

POSSIBLE SOLUTION

 

AND DESCRIPTION

 

 

 

 

 

 

 

D C

F a i l

 

T r a n s i e nt Record:

No action required; this error

Indicates a dc power failure.

display is a record of the start

 

 

 

 

 

time of the failure.

DC Power

Failed: Indicates the

Check the +5 V dc voltage level

absence of +5 V dc on a cabinet.

on the power supply (see Figure

Each cabinet has its own power

4 - 2 ) .

supply; therefore, this may not

 

cause a warm start.

 

 

 

 

 

 

 

DC

Power

Restored:

Indicates

It is possible to produce this error

that +5 V dc has been restored.

when a CP is inserted into a slot

The

“DC Fail Check” log is

with power “On” (not a real

removed. This message keeps a

Problem).

record of dc “hits.”

 

 

 

 

Down Link Buffer Overflow: The

Recoverable; no action required.

down-link

buffer is

receiving

 

messages too fast.

 

 

 

 

 

 

 

DSP

Insane:

Service

Circuit or

If a " DSP Sane " occurred, the

Tone Detector CP problem.

system will remove this error from

 

 

 

 

 

the permanent alarm table. If the

 

 

 

 

 

problem persists, check or

 

 

 

 

 

replace the faulty CP.

 

 

DSP Sane: DSP recovered from

Recoverable; no action required.

an insane

 

condition.

 

 

 

 

Dual Port RAM Read-Back Failure:

Check CP, and replace if required.

Service Circuit dual port RAM

 

problem.

 

 

 

 

 

 

 

 

WART Test

Failed:

Peripheral

This problem affects the tape,

port on CPU/Memory CP has

administration, maintenance and

failed .

 

 

 

SMDR ports. If the problem

 

 

 

 

 

persists, replace the CPU/Memory

 

 

 

 

 

C P .

 

 

 

 

 

 

Page 211