APPENDIX C: System Additions or Changes

5.Insert the CP into the slot with the latch lever opened. Push it in firmly until you feel resistance and the latch lever moves toward its vertical position, flush with the edge of the CP. Push the lever all the vvay to vertical until the latch pin engages. (See figure C-1.)

Add Cabling

If the CP added is a voice or data station CP (ZTN78, ZTN79, TN762, TN726, TN735, TN742, or TN746), you must connect the associated 25-pair receptacle in the back of the cabinet to the SIP with an octopus cable. Follow the instructions under “Connect Cabinets to SIP in Section 2. If the new CP is a trunk CP (ZTN76, ZTN77, TN747, TN760, TN763, or TN753), connect the associated 25-pair receptacle on the back of the cabinet to the TAE with a splitter cable, following the instructions under “Install Equipment Room Trunk Cabling n in Section 2.

For DS1 Interface CP (TN767) connections, see “Install DS1” in “INSTALL EQUIPMENT ROOM TRUNK CABLING” in Section 2.