MAINTENANCE
CLEARING USER-DETECTED TROUBLES
This section presents
Maintenance routines for data terminals and Asynchronous Data Units (ADUs) are not contained in this section (although some basic routines for clearing administration equipment troubles are included). Manuals covering data terminals and data modules are listed in Section 5, “References.” Maintenance for auxiliary devices that are customer provided is the responsibility of the user.
Administration Equipment Troubles
Administration equipment that is connected to the system on a dedicated basis includes the System Administration Terminal (SAT), Station Message Detail Recording (SMDR), and Digital Tape Unit.
Symptoms: .
Terminal dead or functioning intermittently. Messages contain “garbage” characters.
Procedures:
1.Check ac power connection.
2.Check cabling to cabinet.
3.Check administered settings for SAT (see the Administration Manual). Settings should be for
4.Check pin 20 of EIA connector for DTR signal. Signal should be steady at greater than or equal to +3.0 volts with respect to pin 7 ( g r o u n d ) .