![ELECTRICAL REQUIREMENTS (cont.)](/images/new-backgrounds/63291/632919x1.webp)
ELECTRICAL REQUIREMENTS (cont.)
L2 RED | L2 RED | L2 | |
|
| ||
WHITE | WHITE | N | |
NEUTRAL | NEUTRAL | ||
| |||
L1 BLACK | L1 BLACK | L1 | |
|
| ||
GREEN | GREEN | G |
120/208 and 120/240 volt ac single phase, 60 Hz models
Note: This electrical service consists of 3 current carrying conductors (Neutral, L1 and L2) and a separate conductor for earth ground.
| 200 or |
L1 BLACK | 230V |
L2 RED |
|
GREEN | GREEN |
200 and 230 volt ac
single phase, 60 Hz models
Note: This electrical service consists of 2 current carrying conductors (L1 and L2) and a separate conductor for earth ground.
ELECTRICAL HOOK-UP
Damage caused by incorrect electrical connections is not covered by warranty.
1.An electrician must provide electrical service.
2.Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
NOTE - Brewers shipped with a power cord are shipped without a plug on it. Qualified service personnel must select and install the proper UL listed grounding type attachment plug specified on the rear of the brewer.
3.Install the specified plug on the attached power cord.
4.Remove the access panel beneath the sprayheads to gain access to the terminal block.
5.Brewers not equipped with a power cord, feed the wire through the strain relief and connect it to the termi- nal block.
6.Using the above diagrams, connect the desired electrical service to the field wiring terminal block.
7.If wiring the machine for operation on 120/208 or 120/240 volts with a Power Supply Cord, the Power Supply Cord must be UL Listed Flexible Cord Type SO, SJO, SJTO, HSJO or SJOW, No. 12 AWG, 4 Con- ductor, Rated 90° C. Attachment Plug Cap must be UL Listed, NEMA
8.Connect the brewer to the power source and verify the voltage at the terminal block before proceeding.
9.Set toggle switch on component bracket to the appropriate position and replace the access panel.
10.If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumb- ing has been hooked up, the brewer is ready for Initial
WARNING – Electrical connections must be made as specified above. Failure to follow these instructions can
result in personal injury, property or equipment damage.
Page 5 | 35058.2 022410 |
|