Brew cycle will not start (cont.)

Water is not hot or long recovery time.

TROUBLESHOOTING

 

Model ES•1A™

 

 

 

 

Probable cause

 

Remedy

Solenoid valve

Check voltage at terminals. If voltage is

 

present when the dose switch is pressed,

 

disconnect power supply, remove wires

 

from coil terminals and check coil termi-

 

nal continuity. If there is continuity re-

 

place solenoid.

Pump

When start switch is pressed, pump should

 

turn on immediately. If this dies not hap-

 

pen, check voltage at terminal block on the

 

pump. If correct voltage is present, use a

 

flat-blade screwdriver to turn the motor

 

shaft on the rear end of the motor to see if

 

the pump itself is locked up. If the shaft

 

does not turn, replace pump assembly.

Solenoid valve

Remove the solenoid valve and clear it of

 

any obstructions. Rebuild or replace the

 

valve if necessary.

Limit thermostat(s)

Disconnect power supply , remove all wires

 

check across limit terminals for continuity.

 

If no continuity, replace limit thermostat(s).

Tank heater

Check tank heater terminals for correct

 

voltage. If voltage is present and machine

 

is not heating properly, replace tank heater.

 

 

 

 

15