14
6. Repeat steps 1 through 5 as necessary until the correct water flow rate is achieved.
7. Repeat steps 1 through 5 for the remaining dispense positions.
8. Place the Dispense Lockout switch back into the ON position.
Pump Speed Adjustment
1. Disconnect the dispenser from the power source.
2. Remove the drip tray.
3. Remove the two screws securing the splash panel and remove the splash panel
4. Locate the adjustment knobs on the circuit board.
5. Turn the adjustment knobs clockwise to increase speed and counterclockwise to decrease speed.
6. The knob positions directly correspond to dispense station locations.
7. Reinstall the splash panel and drip tray and reconnect the dispenser to the power source.
FIG 14 Adjusting Water Flow
Using 1/4" allen wrench
Mix Ratio Adjust water flow rate to: Product Brix %
(water + concentrate)
2+1 *3.75 fl. oz (111 ml) Prune Juice 16.0%
per 3-second test Other *
Orange Juice 11.8%
4+1 Pineapple Juice 12.8%
Cranberry Fruit Cocktail 14.0%
*4.0 fl. oz (118 ml) Grapefruit Juice 10.6%
per 3-second test Lemonade
5+1 Apple Juice 12.0%
Fruit Punch
Grape Juice 13.0%
3+1 through 7+1 Other *
Above 7+1 *4.0 fl. oz (118 ml) Other *
per 3-second test
High Viscosity Juice 2.25 - 3.0 fl. oz (66.5 - 89 ml) As Required -
per 3-second test
*Maximum flow rate may be less depending on the water pressure supply at each location.
Note: Information for specific products listed in this table is to be used for reference only. Consult the product
label for exact mix ratio and/or brix %. See product label for target brix %.
Water Flow Testing and Adjustment
1. Place a graduated measuring cup or the large chamber of the empty
brixing cup (BUNN-O-MATIC part number 33095.0000) under the ap-
propriate dispense nozzle. Place the Dispense Lockout switch in the
OFF position.
2. Press and release the desired “Product Dispense Switch” three
times.
3. The selected position will dispense water (no concentrate) only for 3
seconds.
4. Measure the water dispensed.
5. Adjust the water flow rate Fig 14, (clockwise to increase flow rate;
counterclockwise to decrease flow rate) to the corresponding product
mix ratio as follows:
ADJUSTMENT & OPTIONAL SETTINGS
P3586