Page 31
SERVICE TOOLS
This function allows the testing of individual com-
ponents and the ability to check switches for proper
function. This function also tests the Soft Heat® server's
status on the brewer (in place or removed), and the
funnel sensor coil's frequency (diagnostic tool for
troubleshooting purposes only).
P2449
P2310
Procedures to set server lockout:
1. Press and hold the ® pad until the display reads
SET NEW RECIPES. Release the ®. Press and
release the ® pad until the display reads SERVER
LOCKOUT.
2. The NO or YES flashes to indicate the current
selection.
3. Select YES to prevent brewing if the Soft Heat
server is not correctly positioned on the brewer
beneath the funnel.
NOTE: If YES is selected and a brew cycle is attempted
with a server not properly placed, the display will read
SERVER NOT IN PLACE.
4. Select NO to allow brewing without a Soft Heat
server in place. This is selected when brewing into
a container other than a Soft Heat Server.
5. When finished, press and release DONE. This will
save the new setting, exit the function screen and
advance to the next. Another alternative is to press
the pad located on the front switch panel to
exit the SERVER LOCKOUT function and return to
the MAIN SCREEN.
SERVER LOCKOUT
This function allows the operator to prevent the
start of a brew cycle if a Soft Heat® server is not
positioned correctly on the brewer.
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)