Page 33
SERVICE TOOLS (cont.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
5. The display should read TEST OUTPUTS.
6. In TEST OUTPUTS screen, press NO. This ad-
vances to TEST SWITCHES.
7. Pressing NO in this screen will advance to the next
function. Press YES in the TEST SWITCHES screen
to test the switches. The display will read NOTH-
ING PRESSED.
8. From this screen, press any of the switches on the
front of the brewer. While the switch is pressed,
the display shows the name of that switch. If the
name does not appear, or if it remains after the
switch has been released, the switch is defective.
Each switch can be tested in this manner.
9. After all switches have been tested, press the
pad located on the front switch panel. This will exit
TEST SWITCHES and return to the MAIN SCREEN.
Procedures to test server:
This function allows the operator to test the opera-
tion of the Soft Heat® server. It will also show if the
server is correctly placed on the brewer stand.
1. Place brew funnels into rails of the brewer.
2. Place a Soft Heat® server beneath the brew funnel.
3. Press and hold the ® pad until the display reads
SET NEW RECIPES. Release the ® pad. Continue
pressing and releasing the ® pad until SERVICE
TOOLS appears.
4. Pressing NO will exit this function and advance to
the next function screen. Press YES to run tests on
various components and outputs within the brewer.
5. The display should read TEST OUTPUTS
6. In TEST OUTPUTS screen, press NO. This ad-
vances to TEST SWITCHES. Press and release NO
once more. The display should now read TEST
SERVER.
7. Press YES in the TEST SERVER screen to show if
a server is in place. The display should read IN
PLACE.
8. Lift and pull the Soft Heat server forward about 2
inches so that the two contacts on the server do
not touch the two contacts on the brewer.
9. The display should then read SERVER REMOVED.
10. After the servers has been tested, press and re-
lease the pad located on the front switch
panel. This will exit TEST SERVER and return to
the MAIN SCREEN.
Procedures to test coil frequency:
1. Place brew funnel into rails of the brewer.
2. Place a Soft Heat® server beneath the brew funnel.
3. Press and hold the ® pad until the display reads
SET NEW RECIPES. Release the ® pad. Continue
pressing and releasing the ® pad until SERVICE
TOOLS appears.
4. Pressing NO will exit this function and advance to
the next function screen. Press YES to run tests on
various components and outputs within the brewer.
5. The display should read TEST OUTPUTS.
6. In TEST OUTPUTS screen, press NO. Continue to
press and release NO until the display reads TEST
FREQUENCY.
7. Press and release YES. The display will show the
frequency of the sensor coil circuits. This is for
diagnostic service use when troubleshooting this
circuit.
8. After the coils have been tested, press and release
either of the pads located on the front switch
panel. This will exit the TEST FREQUENCY func-
tion and return to the MAIN SCREEN.
NOTE: If the operator wishes to test more than one
function in the SERVICE TOOLS section (outputs,
switches, servers, or coil frequency), it is not
necessary to exit the program. Use the flow chart
for SERVICE TOOLS to navigate to a particular
function.
34025 100501