TROUBLESHOOTING (cont.)

 

 

PROBLEM

PROBABLE CAUSE

REMEDY

Consistently high or low beverage level in the dispenser

Spitting or excessive steaming

1.External Strainer/Flow Control (.750 GPM)

1. Lime Build-up

CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral build-up on stainless steel surfaces can ini- tiate corrosive reactions resulting in serious leaks.

(A)Direction of flow arrow must be pointing towards brewer.

(B)Remove the strainer/flow con- trol and check for obstructions. Clear or replace.

Inspect tank assembly for excessive lime deposits. Delime as required.

 

2.

Control Thermostat

Refer to Service - Control Thermo-

 

 

 

stat for testing procedures. See

 

 

 

page 19.

Drip-out time too long

1. Funnel Tip

The brew funnel should be cleaned

 

 

 

thoroughly before each brew cycle

 

 

 

to lessen the chance of tea leaf par-

 

 

 

ticles clogging the drip-out tip.

Sweetener is not working

1.

Sweetener box is empty

Check the Sweetener box to make

 

 

 

sure it is not out of product.

 

2. Flow Adjustment screw is closed

Check the Flow Adjustment screw

 

 

 

to make sure the valve has not

 

 

 

closed.

 

3.

Solenoid is defective

Refer to Service -Sweetener Sole-

 

 

 

noid Valve for testing procedures.

 

 

 

See page 24.

 

3.

The Pump is defective

Check the manufacturers warranty

 

 

 

for additional information on test-

 

 

 

ing and replacement of a defective

 

 

 

pump.

Page 11

10288 031604

 

Page 11
Image 11
Bunn TU3Q service manual Problem Probable Cause