Bunn VP17A service manual Service, Component Access, Contents

Models: VP17A

1 17
Download 17 pages 50.94 Kb
Page 9
Image 9
SERVICE

SERVICE

This section provides procedures for testing and replacing various major components used in this brewer should service become necessary. Refer to Troubleshooting for assistance in determining the cause of any problem.

WARNING - Inspection, testing, and repair of electri- cal equipment should be performed only by qualified service personnel. The brewer should be unplugged when servicing, except when electrical tests are re- quired and the test procedure specifically states to plug-in the brewer.

COMPONENT ACCESS

WARNING - Disconnect the brewer from the power source before the removal of any panel or the replace- ment of any component.

All components are accessible by the removal of the top cover, front inspection panel and warmer assemblies.

The top cover is attached with one #4-40 screw.

The front inspection panel is attached with four #6- 32 screws.

Contents

 

Control Thermostat

10

ON/OFF Warmer Switch

11

Tank Heater

12

Thermal Cut-Offs

13

Warmer Elements

14

Wiring Diagrams

15

P1264

FIG. 1 COMPONENT ACCESS

Page 9

10860.1 091300

Page 9
Image 9
Bunn VP17A service manual Service, Component Access, Contents