Bunn VPR APS service manual Troubleshooting, Problem, Probable Cause, Remedy

Models: VPR APS

1 12
Download 12 pages 8.87 Kb
Page 5
Image 5

TROUBLESHOOTING

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department.

Inspection, testing, and repair of electrical equipment should be performed only by qualified service person- nel.

This brewer is heated at all times. Keep away from combustibles.

WARNING – • Exercise extreme caution when servicing electrical equipment.

Unplug the brewer when servicing, except when electrical tests are specified.

Follow recommended service procedures

Replace all protective shields or safety notices

PROBLEM

PROBABLE CAUSE

REMEDY

Water is not hot

1. Limit Thermostat

Refer to Service - Limit Thermo-

 

CAUTION - Do not eliminate or

stat for testing procedures. See

 

bypass limit thermostat/thermal

page 10

 

cut-off. Use only BOM replace-

 

 

ment part.

 

 

Limit Thermostat - #29329.0001

 

 

2. Control Thermostat

Refer to Service - Control Ther-

 

 

mostat for testing procedures.

 

 

See page 9

 

3.

Tank Heater

Spitting or excessive steaming

1.

Lime Build-up

 

CAUTION - Tank and tank com-

 

ponents should be delimed

 

regularly depending on local

 

water conditions. Excessive min-

 

eral build-up on stainless steel

 

surfaces can initiate corrosive

 

reactions resulting in serious

 

leaks.

 

2.

Control Thermostat

Refer to Service - Tank Heater for testing procedures. See page 10

Inspect the tank assembly for excessive lime deposits. Delime as required.

Refer to Service - Control Ther- mostat for testing procedures. See page 9