TROUBLESHOOTING
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the
•Inspection, testing, and repair of electrical equipment should be performed only by qualified service person- nel.
•This brewer is heated at all times. Keep away from combustibles.
WARNING – • Exercise extreme caution when servicing electrical equipment.
•Unplug the brewer when servicing, except when electrical tests are specified.
•Follow recommended service procedures
•Replace all protective shields or safety notices
PROBLEM | PROBABLE CAUSE | REMEDY |
Water is not hot | 1. Limit Thermostat | Refer to Service - Limit Thermo- |
| CAUTION - Do not eliminate or | stat for testing procedures. See |
| bypass limit thermostat/thermal | page 10 |
|
| |
| ment part. |
|
| Limit Thermostat - #29329.0001 |
|
| 2. Control Thermostat | Refer to Service - Control Ther- |
|
| mostat for testing procedures. |
|
| See page 9 |
| 3. | Tank Heater |
Spitting or excessive steaming | 1. | Lime |
| CAUTION - Tank and tank com- | |
| ponents should be delimed | |
| regularly depending on local | |
| water conditions. Excessive min- | |
| eral | |
| surfaces can initiate corrosive | |
| reactions resulting in serious | |
| leaks. | |
| 2. | Control Thermostat |
Refer to Service - Tank Heater for testing procedures. See page 10
Inspect the tank assembly for excessive lime deposits. Delime as required.
Refer to Service - Control Ther- mostat for testing procedures. See page 9