OPERATION

OPERATION

Problem

Possible Cause

Remedy

 

 

 

Hydraulic Pump not shutting

Using Open Center Valve

Replace Valve or Conversion Plug

off on Closed Center System

 

and Main Relief

 

Open Center Conversion Plug

Replace with Closed Center Plug

 

Pumping over Relief Valve

Replace with No Relief Plug

 

 

 

Oil leaking at hose connection

Connection not tight

Tighten connection

 

Did not use sealant

Apply a good sealant to connection

 

Connection cracked from over-

Replace cracked connection

 

tightening

 

 

Mismatched Connection threads

Use correct connectors

 

or types

 

100 Series 08/10

Operation Section 4-24

© 2010 Alamo Group Inc.

Page 56
Image 56
Bush Hog FC-BL-0002 manual Operation