2-1

Chapter 2

Installing the Modules
The SmartSwitch 9000 module may be installed into any of the 14 slots that are
available. To install, follow the steps below:
1.Remove the blank panel covering the slot that the module is being mounted
in. All other slots must be covered, if modules are not being installed, to
ensure proper airflow and cooling.
2.Carefully remove the module from the shipping box. (Save the box and
packing materials in the event the module must be reshipped.)
3.Attach one end of the ESD wrist strap packaged with the SmartSwitch 9000
chassis to your wrist. Plug the other end into the ESD Wrist Strap Grounding
receptacle in the lower right corner of the SmartSwitch 9000 Chassis shown in
Figure 1.
4.Remove the module from the plastic bag. Observe all precautions to prevent
damage from Electrostatic Discharge (ESD).
5.Carefully examine the module, checking for damage. If any damage exists,
DO NOT install the module. Contact Cabletron Systems Global Call Center
immediately.
6.Before installing the SmartSwitch 9000 cards into the chassis, ensure that the
bottom and top plastic tabs are unlocked. Slide the card into an available slot
and ensure that the circuit card is between the card guides, as shown in Figure
1. Check both the upper and lower tracks. Take care that the module slides in
straight and engages the backplane connectors properly. Lock down the top
and bottom plastic tabs at the same time, applying even pressure.