22 Installation ELS100-24TXM
Memory
Memory tests on the CPU RAM are performed after the ser ial port
test. No results are displayed on the console.
After these two tests are performed, the operational software of the switch
is loaded. A series of more extensive diagnostic tests are then conducted
during which the Test LED remains lit. The results of the tests are
displayed on the terminal. If all tests pass, the Test LED turns off. When
all tests are complete, the system is functional and the user interface i s
ready to receive commands at the console.
Network Cable Requirements

Copper

Table 2-1 specifies the cable types and length constraints for the copper
interfaces on the ELS100-24TXM.
Table 2-1. Copper Cable Specifications

Fiber

Table 2-2 specifies the fiber types and length constraints on the
ELS100-24TXM.
Table 2-2. Fiber Specifications
Interface Type Cable Requirement Maximum Length
10Base-T Cate
g
ory 3 or 5 Unshielded Twisted
Pair (UTP) 100m (328 ft.)
100Base-TX Cate
g
ory 5 UTP 100m (328 ft.)
Interface Type Fiber Type Fiber Diameter
(microns) Maximum Length
100Base-FX multi-mode 62.5 2,000m (6,560 ft.)
100Base-FX sin
g
le-mode 9 20,000m (65,600 ft.)