LANVIEW Status Monitoring System

LANVIEW LEDs

Figure 1-2 LANVIEW LEDs

The following discusses the function of each LANVIEW LED on the FOMIM (Figure 1-2). Note that there is one Link OK (LNK) and one Receive (RCV) LED for each port on the MIM, as well as one Error (ERR) and one Collision (CLN) LED for the entire MIM.

Link OK (LNK) LED

When lit, this green LED indicates that a link has been established between the receive circuitry of the FOMIM and the transmit circuitry of the fiber optic device at the other end of the link segment. This LED remains lit as long as the link is maintained.

Receive (RCV) LED

When lit, this yellow LED indicates that a data packet is being received on that port. The flash of the LED is pulse stretched for viewing effect.

Collision (CLN) LED

When lit, this red LED indicates that a collision is occurring on one of the fiber segments attached to a fiber optic port on the FOMIM. The flash of the LED is pulse stretched for viewing effect.

FOMIM User’s Guide

1-5

Page 12
Image 12
Cabletron Systems FOMIM-32, 36, 38 manual Lanview Status Monitoring System