| Using LANVIEW |
| Table | ||
|
|
|
|
|
|
| Error |
Led | Color | Description | Condition/Recommended |
|
|
| Action |
|
|
|
|
LNK | Green | When on, a link is | If off, the link between the port |
(Link/ |
| established | and fiber device has been |
Fiber |
| between the | broken. |
Port) |
| FOMIM Fiber port |
|
|
| and the fiber device | Check the connectors at each |
|
| at the other end of | end of the segment to ensure |
|
| the segment. LED is | that they are free of dust. Clean |
|
| on as long as the | the connectors if necessary. |
|
| link is maintained. | Reconnect the segment and |
|
|
| check the Link LED again. |
|
|
|
|
RCV | Yellow | When flashing the | If off, the FOMIM is not |
(Receive) |
| FOMIM is receiving | receiving packets. |
|
| data packets from |
|
|
| segments connected | Check that the module is firmly |
|
| to the associated | installed in the MMAC. |
|
| port. |
|
|
|
|
|
CLN | Red | When flashing, a | Excessive flashing or on solid |
(Collision |
| collision is being | indicates excessive collisions. |
Present) |
| detected on one or |
|
|
| more segments |
|
|
| connected to the |
|
|
| MMAC. Note that |
|
|
| periodic flashing is |
|
|
| normal. |
|
|
|
|
|
ERR | Red | Remains lit when the |
|
(Error) |
| temperature within |
|
|
| the MMAC chassis |
|
|
| rises above 40°C. |
|
|
|
|
|
If you are not able to resolve a problem with your FOMIM, call Cabletron Systems Technical Support for assistance (see Chapter 1, Section 1.6, Getting Help).