Cabletron Systems FRX6000 LAN Card Connectors, Rack-MountedI/O Boxes, WAN Port Interface Cables

Models: FRX6000

1 9
Download 9 pages 31 Kb
Page 4
Image 4
Figure 2 LAN Card Connectors

Ethernet

Token Ring

RJ45

 

 

DB9F

DB15F

RJ45

 

BNC

 

Figure 2 LAN Card Connectors

3.Assuming the node will be mounted in a rack, it can be secured to slides, or set on a fixed or slide-out shelf. The node can also be mounted directly to the cabinet frame, but this makes access difficult.

Retaining Screw

 

 

Service

 

Cable

 

 

 

Clamp

 

 

 

 

 

 

 

 

 

 

 

 

RLP Cable

 

 

Loop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I/O Box

Support Rails

Interface Cables

Cable Tie

Do not support a rack-mounted node only in the front. It must be supported at both front and rear.

4.Plug all cables into the appropriate connectors at the rear of the FRX6000, and tighten the retaining screws on each cable connector that has them. (It does not matter which end of an RLP cable plugs into the RLP.) Figure 1 shows the connectors on the rear of the chassis, and Figure 3 shows some cable retaining screws.

Figure 3 Rack-Mounted I/O Boxes

In the above example, both Line Interface Cards (LICs) on the RLP are 4-port LICs (V.35, RS-232, or RS-422). A T1 or E1 LIC includes an RJ45 adapter instead of an RLP cable and I/O box. (The T1/E1 cable is not supplied.)

5.Plug the RLP cables into their associated I/O boxes and tighten the retaining screws. If the assembly is being rack mounted, attach the I/O boxes and cables as shown in Figure 3, using the hardware provided.

Leave a 24–36 inch service loop in each cable between the mounting rails and the rear of the node, to allow the unit to be pulled forward.

Table 1 WAN Port Interface Cables

Cable Type

Cabletron Part Number

 

 

V.35 DTE

FRX-V35DTE-CAB 1

V.35 DCE

FRX-V35DCE-CAB

 

 

RS-232 DTE

FRX-232DTE-CAB

 

 

RS-232 DCE

FRX-232DCE-CAB

 

 

RS-449 DTE

FRX-449DTE-CAB

 

 

RS-449 DCE

FRX-449DCE-CAB

 

 

X.21 DTE

FRX-X21DTE-CAB

 

 

X.21 DCE

FRX-X21DCE-CAB

 

 

* One V.35 DTE cable is shipped as standard equipment with each FRX6000.

Installation & Setup Guide

3

4

FRX6000

Page 4
Image 4
Cabletron Systems FRX6000 manual LAN Card Connectors, Rack-MountedI/O Boxes, WAN Port Interface Cables, Cable Type