Chapter 3

Operation

The 9T122-24 MicroLAN Module provides connectivity between the front panel Token Ring(s) and the FDDI rings on the backplane (FNB-1 or FNB-2).

SmartSwitch 9000 modules connect to either the Internal Network Bus (INB) or the Flexible Network Bus (FNB) bus. The 9T122-24 module connects to the FNB bus. Figure 3-1 is a block diagram of the module. The front panel may be configured as one Token Ring (factory default) or as two rings. In the two-ring configuration, the rings function as individual networks, each with 12 ports. Bridging/Routing may occur between these two rings and/or to any other SmartSwitch 9000 module via the FNB.

DC/DC

Converter

Twelve

Front Panel

Connections

Twelve

Front Panel

Connections

System

Diagnostic

Controller

i960 PLUS Core

SMB-1

SMB-10

FNB-1 or

FNB-2

Figure 3-1. 9T122-24 Block Diagram

3-1

Page 21
Image 21
Cabletron Systems STH-24 manual Operation, T122-24 Block Diagram