Models PW1625, PW1825, and PW1835

Assembly and Preoperation (Continued)

6.Attach lance to gun (see Figure 12).

7.Attach garden hose to unit (see Figures 14 and 15).

Trigger Safety Latch

In the engaged position, the trigger safety latch prevents the gun from being triggered accidentally. Push the latch fully up to engage it (See Figure 17).

Always engage the trigger safety latch when the unit is not in use.

Pump Gasket

Hose Gasket

Extra Gasket

Figure 15 - Garden hose gasket instructions

SafetyLocklock

Triggertrigger

HighHighPressureOutlet

Figure 16 - Attach high pressure hose to high pressure outlet

Figure 17 - Trigger safety latch

Operation

Surface Preparation

The following cleaning procedure will help you organize your cleaning task and ensures that you will achieve the best results in the shortest amount of time. Remember to use the spraying / cleaning techniques mentioned in the following section.

Before starting a pressure washer cleaning job, prepare the surface you intend to clean. Clear furniture from the area and make sure that all windows and doors are closed tightly. Also, protect all plants and trees near the cleaning area with a drop cloth. A covering ensures that your plants won’t be sprayed by the detergents.

Start Up

ALWAYS use this start up procedure to ensure that the unit is started safely and properly.

If water has frozen in the pressure washer, thaw the pressure washer in a warm room before starting. DO NOT pour hot water on or into the pump;

internal parts will be damaged.

1.Ensure that the power switch is in the “OFF” position.

2.Attach swivel adapter to pump water inlet, if not already attached. Notice the swivel adapter is marked with the words pump and hose. Make sure to connect pump side of adapter to pump water inlet to prevent damage to the threads.

3.Attach a garden hose to the inlet side of the pump and connect it to the water supply. Use a hose with an internal diameter (I.D.) of 5/8 in. (1.58 cm) and a length of 50 ft. (15 m) or less.

Some local plumbing codes require backflow prevention when connecting to a fresh water supply. Install a backflow preventer upstream

from the pump if necessary.

a.If inlet water pressure is over 100 psi, install a regulating water valve at the garden hose connection.

b.Do not exceed 100˚ F (38˚ C) inlet water temperature.

NOTE: The inlet water supply must have a minimum flow rate of 5 gpm (19 lpm).

www.chpower.com 11