WL Series

Assembly (Con't)

Repeat on the opposite side.

3.When assembled, the tank must sit level or slope slightly towards the drain cock to allow the tank to drain properly.

Installation

LOCATION

It is extremely important to install the compressor in a clean, well ventilated area where the surrounding air temperature will not be more than 100°F.

A minimum clearance of 18 inches between the compressor and a wall is required because objects could obstruct air flow.

Do not locate the

! CAUTION compressor air inlet near steam, paint spray, sandblast areas or any other source of contamination. This debris will damage the motor.

ELECTRICAL INSTALLATION

All wiring and

! WARNING electrical connections should be performed by a qualified electrician. Installation must be in accordance with local codes and national electrical codes.

! CAUTION

 

 

Never use an extension

STOP!

cord with this product. Use

 

additional air hose instead

 

of an extension cord to

 

 

avoid power loss and permanent motor damage. Use of an extension cord voids the warranty.

GROUNDING INSTRUCTIONS

1.This product is for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug illustrated in Fig. 3. Make sure the product is connected to an outlet having the same configuration as the plug. This product must be grounded. In the event of an electrical short circuit, grounding reduces risk of electrical shock by providing an escape wire for electric current. This product is equipped with a cord having a grounding wire with an appropriate

grounding plug. Plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Grounding

Pin

TEST RESET

Grounded Outlet

Figure 3 - Grounding Method

!DANGER

Improper use of grounding plug can result in a possible risk of electrical shock!

 

Do not use a

! DANGER

grounding adapter

 

with this product!

2.If repair or replacement of cord or plug is necessary, do not connect grounding wire to either flat blade terminal. The wire with insulation having an external surface that is green (with or without yellow stripes) is the grounding wire.

! WARNING

Never connect

green (or green and

yellow) wire to a live terminal.

3.Check with a qualified electrician or serviceman if grounding instructions are not completely understood, or if in doubt as to whether product is properly grounded. Do not modify plug provided; if it will not fit outlet, have proper outlet installed by a qualified electrician.

WIRING

1.Local electrical wiring codes differ from area to area. Source wiring, plug and protector must be rated for at least the amperage and voltage indicated on motor nameplate, and meet all electrical codes for this minimum.

2.Use a slow blow fuse or a circuit breaker.

Overheating, short ! CAUTION circuiting and fire

damage will result from inadequate wiring, etc.

NOTE: 120 volt, 15 amp units can be operated on a 120 volt circuit under the following conditions:

a. No other electrical appliances or lights

are connected to the same branch circuit.

b. Voltage supply is normal.

c. Circuit is equipped with a 15 amp circuit breaker or a 15 amp slow blow fuse.

3.If these conditions cannot be met or if nuisance tripping of current protection device occurs, it may be necessary to operate compressor from a 120 volt, 20 amp circuit.

Operation

Pressure Switch - Auto/Off Switch - In the AUTO position, the compressor shuts off automatically when tank pressure reaches the maximum preset pressure. In the OFF position, the compressor will not operate. This switch should be in the OFF position when connecting or disconnecting the power cord from the electrical outlet or when changing air tools. Regulator - The regulator controls the amount of air pressure released at the hose outlet.

ASME Safety Valve - This valve automatically releases air if the tank pressure exceeds the preset maximum. Discharge Tube - This tube carries compressed air from the pump to the check valve. This tube becomes very hot during use. To avoid the risk of severe burns, never touch the discharge tube.

Check Valve - A one-way valve that allows air to enter the tank, but prevents air in the tank from flowing back into the compressor pump. Handle - Designed to move the compressor.

Never use the

! WARNING handle on wheeled units to lift the unit completely off the ground.

Drain Petcock - This valve is located on the bottom of the tank. Use this valve to drain moisture from the tank daily to reduce the risk of corrosion.

Reduce tank pressure below 10 PSI, then drain moisture from tank daily to avoid tank corrosion. Drain moisture

www.chpower.com

3

Page 3
Image 3
Campbell Hausfeld IN203203AV 11/00 operating instructions Installation, Operation, WL Series

IN203203AV 11/00 specifications

The Campbell Hausfeld IN203203AV 11/00 is a powerful and versatile air compressor designed to meet the demands of both DIY enthusiasts and professional tradespeople alike. Known for its robust construction and reliable performance, this model stands out in a crowded market, offering an array of features tailored to diverse applications.

One of the key characteristics of the IN203203AV is its oil-free pump design, which significantly reduces maintenance requirements. This feature is particularly advantageous for users seeking hassle-free operation without sacrificing durability or performance. The oil-free technology ensures that users can enjoy cleaner air output, making it an excellent choice for tasks requiring precision, such as painting or inflating.

With a powerful motor that delivers a substantial amount of output, the IN203203AV can power various pneumatic tools, including nailers, staplers, and impact wrenches. It boasts a high flow rate, allowing for quicker recovery times between tool usage, which enhances productivity in demanding work environments.

Portability is another standout feature. The compact design and lightweight construction make it easy to transport, whether from the garage to the job site or around the workshop. The integrated handle and rubber wheels facilitate effortless mobility, ensuring that users can move it without strain.

Safety and convenience are also addressed with features like the built-in pressure regulator, which allows for precise air pressure adjustments based on specific tool requirements. This not only protects tools from damage but also enhances their longevity. Additionally, the IN203203AV is equipped with multiple outlet ports, making it convenient to connect various tools simultaneously.

The quiet operation of this compressor is another significant selling point. Operating at lower noise levels compared to many counterparts, it allows for prolonged use without disturbing the environment, making it ideal for indoor tasks or residential areas.

In conclusion, the Campbell Hausfeld IN203203AV 11/00 air compressor is a reliable and efficient choice for those looking for a machine that combines portability, ease of use, and versatile functionality. Its thoughtful design elements, coupled with the innovative oil-free pump technology, underscore its commitment to quality and user satisfaction in any setting. Whether used for home improvement projects or professional applications, this compressor is engineered to meet a broad range of air compression needs.