Operating Instructions and Assembly Instructions

Airless Paint Sprayers

Preparation (Continued)

1.Place both suction and bypass tubes in cleaning solvent.

2.Turn prime/spray control to the Prime position.

3.Turn power switch to the ON position.

4.Turn pressure to High (completely clockwise). In a few seconds, cleaning solvent will begin to move up through the tube. Allow the fluid to circulate for one minute to ensure all air has been exhausted from the pump.

5.Turn prime/spray control to Spray position. Watch for any fluid leaks (See Troubleshooting Chart if leaks occur).

NOTE: If unit is building pressure properly the pump should turn off, which indicates it has reached its user set pressure.

6.When flushing the system with cleansing fluid (either prior to use with paint or during cleaning process) the spray tip can remain in the clean position.

7.Point spray gun into an empty waste bucket and pull trigger. To reduce splashing, direct the fluid stream along the inside of the bucket wall and well above the fluid level.

Starting Instructions

1

Place Suction Tube

and Bypass Tube in

Solvent

23

Turn Prime/ Spray

 

Control

 

to PRIME

Power Switch

(knob is vertical)

Location

 

5 4

Turn Pressure

 

to HIGH

Turn Prime/ Spray

(completely clockwise)

Control

 

to SPRAY

 

(knob is horizontal)

6

7

Tip in

While Pulling Trigger,

Direct Fluid Stream Along

Cleaning

Inside of Bucket

Position

 

www.chpower.com

7