Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action(s)

 

 

 

 

 

Pressure washer does

1.

Plug is not well connected or electric

1.

Check plug, socket and fuses

not start up

 

socket is faulty

 

 

 

2.

The main voltage supply is too low

2.

Check that the main supply voltage is

 

 

 

 

adequate

 

3.

Thermal safety switch has tripped

3.

Switch off the unit and allow the

 

 

 

 

motor to cool down. Leave the lance

 

 

 

 

open.

 

4.

GFCI has tripped

4.

Push reset button

 

 

 

 

 

Pump does not reach

1.

Water inlet filter is clogged

1.

Clean water inlet filter

necessary pressure

2.

Pump sucking air from connection or

2.

Check that connections and locking

 

 

 

hoses

 

ring are properly tightened

 

3.

Suction delivery valves are clogged

3.

Call 1-800-330-0712

 

 

or worn out

 

 

 

4.

Lance nozzle not correct or worn out

4.

Call 1-800-330-0712

 

 

 

 

 

Fluctuating pressure

1.

Pump sucking in air

1.

Check that hoses and connections are

 

 

 

 

tight

 

2.

Valves dirty, worn out or stuck

2.

Call 1-800-330-0712

 

3.

Water seals worn out

3.

Call 1-800-330-0712

 

 

 

Excessive water leak-

Water seals worn out

Call 1-800-330-0712

ing from pump

 

 

 

 

Motor stops suddenly

Thermal safety switch has tripped due to

 

overheating

1.Check that the main supply voltage corresponds to the specifications

2.Switch the unit off and let it cool down