Operating Instructions and Parts Manual

Pre-Operation (Continued)

7. Install quick connect tip (See Figure 7).

TRIGGER SAFETY LATCH

 

 

In the engaged position, the trigger

 

 

 

 

safety latch prevents the gun from being

 

 

triggered accidentally. Push the latch fully

 

 

 

 

 

 

 

 

 

 

 

 

 

Engaged

 

 

 

 

 

 

 

 

 

 

Figure 8 - Trigger locked

Figure 7 - Quick Connect Tip

up to engage it (See Figure 8 and 9).

Always engage the trigger safety latch when the unit is not in use.

Disengaged

Figure 9 - Trigger unlocked

Operation

1. Surface Preparation

The following cleaning procedure will help you organize your cleaning task and ensures that you will achieve the best results in the shortest amount of time. Remember to use the spraying / cleaning techniques mentioned in the following section.

Before starting a pressure washer cleaning job, prepare the surface you intend to clean. Clear furniture from the area and make sure that all windows and doors are closed tightly. Also, protect all plants and trees near the cleaning area with a drop cloth. A covering ensures that your plants won’t be sprayed by the detergents.

2. Start Up

ALWAYS use this start up procedure to ensure that the unit is started safely and properly.

If water has frozen in the pressure

washer, thaw the pressure washer in a warm room before starting. DO NOT pour hot water on or into the pump; internal parts will be damaged.

1.Check engine oil levels. Add oil as necessary.

2.Check fuel level. Add unleaded gasoline (rated 86 octane or higher) as required.

DO NOT refuel a hot engine. Refueling a hot engine could cause a fire. Use only

fresh, clean regular or unleaded gasoline. Close the fuel shutoff valve during refueling.

3.Attach a garden hose to the inlet side of the pump and connect it to the water supply. Use a hose with an internal diameter (I.D.) of 5/8 in. (1.58 cm) and a length of 50 ft. (15 m) or less.

Some local plumbing codes

require backflow prevention when connecting to a fresh water supply. Install a backflow preventer upstream from the pump if necessary.

a. If inlet water pressure is over 100 psi, install a regulating water valve at the garden hose connection.

b.Do not exceed 100˚ F (38˚ C) inlet water temperature.

NOTE: The inlet water supply must have a minimum flow rate of 5 gpm (19 lpm).

4. Turn the water supply ON.

Never run the unit dry. Be sure the

water supply is completely turned on before operating the unit.

5.Trigger the gun until water sprays from the tip indicating that all air is purged from the system. Set the trigger safety latch.

6.Open the fuel shutoff valve by turning the lever to the right/“ON” position. Close the choke (if the engine is cold) by moving the choke lever fully to the left. Move the throttle fully to the left to the “Run” or “Rabbit” position. Turn the ON/OFF swirch to the “ON” position.

Figure 10 - Throttle