Maintenance Schedule

 

 

Maintenance Schedule

Action needed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Daily

 

 

 

 

 

 

• Check water inlet screen and

 

 

 

 

 

filter.

 

 

 

 

 

• Check engine oil levels. Fill as

 

 

 

 

 

 

necessary.

 

 

 

 

 

• Check gasoline level. Fill as

 

 

 

 

 

 

necessary.

 

 

 

After first 5 hours of

 

• Change engine break-in oil.

 

 

 

operation

 

 

Use 10W-30 automotive

 

 

 

 

 

 

 

 

 

 

 

 

detergent oil. See your Honda

 

 

 

 

 

 

Owner’s manual for specific

 

 

 

 

 

 

information.

 

 

 

 

 

 

 

 

 

Every 25 hours of

 

• Change oil if operating under

 

 

 

operation

 

 

heavy load or high ambient

 

 

 

 

 

 

temperature.

 

 

 

 

 

• Clean or replace paper air

 

 

 

 

 

 

cleaner cartridge. Tap gently

 

 

 

 

 

 

to remove dirt.

 

 

 

Every 50 hours of

 

• Change oil.

 

 

 

operation

 

• Replace spark plug.

 

 

 

Each 100 hours of

 

• Replace paper air cleaner

 

 

 

operation or every 3

 

 

cartridge.

 

 

 

months

 

• Change engine oil.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical and Consumer Information
Horizontal Oriented Pressure Washers

 

 

 

 

 

 

 

 

Engine Oil Type

SAE 10W-30

 

 

 

 

 

(See Honda’s Owner Manual)

 

 

 

 

Engine Oil Capacity

 

 

 

 

 

Honda GX160

20 fl. oz.

 

 

 

 

Honda GX270

37 fl. oz.

 

 

 

 

Honda GX390

37 fl. oz.

 

 

 

 

 

 

 

 

 

 

Engine Fuel Capacity

 

 

 

 

 

Honda GX160

3.3 US quarts (3.1 L)

 

 

 

 

Honda GX270

5.6 US quarts (5.3 L)

 

 

 

 

Honda GX390

6.4 US quarts (6.1 L)

 

 

 

 

 

 

 

 

 

 

Pump Oil Type

CAT pump oil

 

 

 

 

 

 

 

 

 

 

Pump Oil Capacity

 

 

 

 

 

CAT Pumps

 

 

 

 

 

3DNX25

8.5 fl. oz.

 

 

 

 

3SPX30

10.15 fl. oz.

 

 

 

 

66DX35

18 fl. oz.

 

 

 

 

Pump Detergent Suction

 

 

 

 

 

Water to detergent ratio

10 to 1 (10% detergent)

 

 

 

 

Water Supply Requirements

 

 

 

 

 

Minimum inlet pressure

20 psi

 

 

 

 

Maximum inlet pressure

100 psi

 

 

 

 

Maximum inlet temperature

100˚ F

 

 

 

 

Minimum inlet flow rate

5 gpm

 

 

 

 

Inlet garden hose size

5/8 in. I.D.

 

 

 

 

Maximum inlet garden

 

 

 

 

 

hose length

50 ft

 

 

 

 

 

 

 

 