INSTALLATION INSTRUCTIONS

SPACE FOR FIXING

The cooker can be close fitted below hotplate level. This requires a minimum distance of 503mm between cupboard units of hotplate height.

When installing next to a tall cupboard, partition or wall, for a minimum distance of 400mm above hotplate level, allow a side clearance of at least 65mm.

The diagram below illustrates the minimum clearance between the cooker and adja- cent walls, cupboards etc.

The wall behind the cooker, 150mm below the hotplate and 450mm above, and the width of the cooker, must be a non-combustible material such as ceramic wall tiles.

If the cooker is to be fitted close to a corner on the left hand side, ensure that there is a clearance of at least 50mm to allow the main oven door to open fully for when remov- ing oven shelves.

400 mm Min

mm Min

 

750

65 mm Min

 

503 mm Min

COOKER HOODS

If a cooker hood is to be installed, refer to the cooker hood manufacturers’ instructions regarding fixing height.

22

Page 22
Image 22
Cannon 10510G, 10512G, 10515G, 10518G installation instructions Space for Fixing, Cooker Hoods