TECHNICAL DATA

INSTALLATION INSTRUCTIONS

TECHNICAL DATA

 

 

 

 

 

 

 

DIMENSIONS

 

 

 

 

 

 

 

Height

900 - 915mm

Width

600mm

 

Depth

595mm (excluding door handles)

GENERAL

Rp

 

/

 

(

/ ” BSP female)

Gas connection

 

 

 

 

1

 

2

1

 

2

Pressure test point

Grill injector

Gas rate adjustment

None

 

 

 

Aeration adjustment

None

 

 

 

Battery

1.5V Alkaline AA.

 

NATURAL GAS

LPG MODELS

 

 

MODELS

 

 

 

 

 

 

 

 

 

 

 

 

HEAT

INJECTOR

HEAT

INJECTOR

 

INPUT

INPUT

BURNER

 

 

 

 

 

 

 

 

 

 

 

HOTPLATE

3.0 kW

134

2.9 kW (220g/h)

90

Front left and rear right

 

 

 

 

 

 

 

 

 

HOTPLATE

1.8 kW

109

1.8 kW (130g/h)

72

Front right and rear left

 

 

 

 

 

 

 

 

 

GRILL

3.8 kW

150

3.3 kW (235g/h)

95

 

 

 

 

 

MAIN OVEN

2.7 kW

120

2.4 kW (175g/h)

75

 

 

 

 

 

TOP OVEN

2.0 kW

100

2.0 kW (145g/h)

60