Technical information
Electrical connection
GB
!Arrange the electrical power supply within the decorative flue dimensions.
!When making the electrical connections, check that the voltage values correspond to those indicated on the data plate inside the appliance itself.
!In case your appliance is not furnished with a non separating flexible cable and has no plug, or has not got any other device ensuring omnipolar disconnection from the electricity main, with a contact opening distance of at least 3 mm, such separating device ensuring disconnection from the main must be included in the fixed installation.
!If your unit features a power lead and plug, position this so the plug is accessible.
Power cable
!Warning: The hood is fitted with a specially prepared cable; if the cable is damaged, it must be replaced with a cable or special cable assembly, available at the manufacturer or its technical service.
Technical data
| Model | BHC90 | BHC110 | |
|
|
|
| |
| Dimensions | width 89.8 cm | width 109.8 cm | |
|
| height 83 / 125 cm | height 83 / 125 cm | |
|
| depth 49 cm | depth 49 cm | |
|
| Outlet pipe diameter 15 cm | Outlet pipe diameter 15 cm | |
|
|
|
|
|
| Gross weight | 24.5 Kg | 29.2 Kg | |
|
|
|
| |
| Absorption | Total 410 W | Total 410 W | |
|
| Motor 1x370 W | Motor 1x370 W | |
|
| Lamps 2x20 W | Lamps 2x20 W | |
|
|
|
| |
| Flow rate | 625 m3/h | 625 m3/h | |
|
|
|
|
|
| Grease filters |
|
|
|
| Suction |
|
|
|
| surface area | 461 cm2 | 544 cm2 | |
|
|
|
|
|
6