Carrier 2025, 1625 Use of Furnace Adapters, Use of Return Duct Adapters, Wiring, Gapa

Models: 2025 1625

1 10
Download 10 pages 26.96 Kb
Page 5
Image 5
Fig. 5 - Use of Furnace Adapters

Furnace

Adapters

Airflow

Airflow

A05274

Fig. 5 - Use of Furnace Adapters

Note (optional): Slip return duct adapters onto flanges on air return duct side

A05277

Fig. 6 - Use of Return Duct Adapters

Step 9Wiring

!WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.

Before installing or servicing system, always turn off main power to system. There may be more than 1 disconnect switch.

!CAUTION

EQUIPMENT DAMAGE HAZARD

Failure to follow this caution may result in equipment damage or improper operation.

This unit cannot be powered directly from blower motor leads. Voltages can exceed 190 VAC (120v motors). Do not wire directly to blower motor. Wiring to blower motor will damage power supply and void warranty.

a.Ensure power has been removed from the heating and cooling system.

b.Turn the Infinityt Air Purifier power switch off.

c.Connect the power cord to the power supply connector (see Fig. 7).

d.Route the power cord through nearest cabinet hole and protect with enclosed cable connector. Zip ties have been enclosed to secure the power cord to the side of the power supply.

e.Attach the quick connect terminals to the furnace EAC-1 and EAC-2 spade connections. Attach the ground ring to furnace chassis ground.

NOTE: The Infinityt Air Purifier is to be powered by 115v/60 Hz.

NOTE: The Infinityt Air Purifier should only be powered when airflow is present. The furnace control EAC spade connections provide power only when the furnace blower is operating. If EAC connections are not available, an alternative airflow sensing mechanism must be used to ensure the Infinityt Air Purifier is only powered when airflow is present. Contact a local Carrier distributor for information on approved alternatives.

!CAUTION

UNIT COMPONENT DAMAGE HAZARD

Failure to follow this caution may result in equipment damage or improper operation.

Black Lead - Connect to HOT (L1) or EAC-1 when provided.

White Lead - Connect to Neutral (L2) or EAC-2 when provided.

Green/Ground Lead - Connect to Appliance Ground (Chassis)

GAPA

5

Page 5
Image 5
Carrier 2025, 1625 Use of Furnace Adapters, Use of Return Duct Adapters, Wiring, Equipment Damage Hazard, Gapa