NOTE: Make sure that the arrows on the air purifier cartridge point toward the furnace. This should be in the same direction as airflow.
Step
Step
Step
Door Switch Magnet
A06053
Fig. 9 - Door Switch Magnet
TROUBLESHOOTING
!CAUTION
SAFETY HAZARD
Failure to follow this caution may result in personal injury or equipment damage.
The following instructions are for use by qualified personnel only.
!WARNING
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or death.
The following procedures will expose electrical components. Disconnect power between checks and proceed carefully.
The Infinityt Air Purifier is equipped with a power indicator light located on the door (see Fig. 8). This power indicator light will illuminate when the Infinityt Air Purifier door is installed, the power switch is in the on position, AND the furnace blower is running. If the power indicator light is not illuminated, follow the troubleshooting steps below.
Step
NOTE: A magnet in the door (see Fig. 9) is used to activate a safety switch in the power supply when the door is installed. The power supply will not energize the air purifier unless the safety switch is activated.
Step
Step
NOTE: Power will not be supplied to the Infinityt Air Purifier from the furnace controls EAC terminals unless the blower is running.