Table 2A — Contents of Accessory Kit, Part No. 00EFN900002700A

PART NUMBER

 

QUANTITY

DESCRIPTION

USAGE

00PSN500171700A

 

 

Tube assembly including solenoid valve,

One per circuit (circuit A and B for 30XA400).

 

2

Cooler shell minimum load port, connect to

 

ball valve, and 90 degree bend tube assembly

 

 

 

 

30GX5034892 adapter.

 

 

 

 

 

30GX5034892

 

2

1 in. -14 ORS x 1/2 in. NPT adapter

One per circuit. Cooler shell minimum load port.

00PPG000011600A

 

2

Solenoid coil assembly

One per circuit. Plug onto solenoid valve stub

 

on 00PSN500171700A tube assembly.

 

 

 

 

 

KA66AA062

 

4

5/8 in. tube clamp

Secure minimum load piping to the frame

 

as required.

 

 

 

 

 

DE40BA705

 

2

1 1/8 in. x 1 1/8 in. x 5/8 in. Tee

One per circuit. Discharge manifold on the side

 

of condenser coil V.

 

 

 

 

 

TH70400410

 

2

Cable assembly

One per circuit. Connect to solenoid coil

 

assembly and terminal block TB5 in control box.

 

 

 

 

 

00PPN500000401A

 

4

No. 10 Screw

Mount tube clamps

32GB500432E

 

1

HGBP/Pump board

Mount in control box

TH70400864

 

1

Harness assembly

Wiring between TB5 and HGBP/Pump board

HH83ZB001

 

1

24 v circuit breaker (CB14)

Mount on display bracket in control box

A6X10004352

 

4

No. 8 screw

Mount HGBP/Pump board

A6X10004434

 

4

Board mounting standoff

Mount HGBP/Pump board (30XA140-240,400:

 

all voltages and 30XA080-120: 200/230 v, 380 v)

 

 

 

 

 

TH70400852

 

1

Communication cable assembly

30XA140-240,400: all voltages and

 

30XA080-120: 200/230 v, 380 v

 

 

 

 

 

HY89TB010

 

3

Wire nut

Splice communication cable

 

(30XA080-120: 460 v, 575 v)

 

 

 

 

 

 

LEGEND

 

 

 

HGBP — Hot Gas Bypass

 

 

ORS

O-Ring Seal

 

 

 

TB

Terminal Block

 

 

 

Table 2B — Contents of Accessory Kit, Part No. 00EFN900002800A

PART NUMBER

 

QUANTITY

DESCRIPTION

USAGE

00PSN500171700A

 

 

Tube assembly including solenoid valve,

One per circuit (circuit A and B for 30XA400).

 

2

Cooler shell minimum load port, connect to

 

ball valve, and 90 degree bend tube assembly

 

 

 

 

30GX5034892 adapter.

 

 

 

 

 

30GX5034892

 

2

1 in. -14 ORS x 1/2 in. NPT adapter

One per circuit. Cooler shell minimum load port.

00PPG000011600A

 

2

Solenoid coil assembly

One per circuit. Plug onto solenoid valve stub

 

on 00PSN500171700A tube assembly.

 

 

 

 

 

KA66AA062

 

4

5/8 in. tube clamp

Secure minimum load piping to the frame

 

as required.

 

 

 

 

 

DE40BA705

 

2

11/8 in. x 11/8 in. x 5/8 in. Tee

One per circuit. Discharge manifold on the side

 

of condenser coil V.

 

 

 

 

 

TH70400410

 

2

Cable assembly

One per circuit. Connect to solenoid coil

 

assembly and terminal block TB5 in control box.

 

 

 

 

 

00PPN500000401A

 

4

No. 10 Screw

Mount tube clamps

32GB500432E

 

1

HGBP/Pump board

Mount in control box

TH70400864

 

1

Harness assembly

Wiring between TB5 and HGBP/Pump board

HH83ZB001

 

1

24 v circuit breaker (CB14)

Mount on display bracket in control box

A6X10004352

 

4

No. 8 screw

Mount HGBP/Pump board

A6X10004434

 

4

Board mounting standoff

Mount HGBP/Pump board (30XA260-300,400,450,

 

500: all voltages)

 

 

 

 

 

TH70400852

 

1

Communication cable assembly

30XA260-300,400,450,500: all voltages

HY89TB010

 

3

Wire nut

Splice communication cable

 

LEGEND

 

 

 

HGBP — Hot Gas Bypass

 

 

ORS

O-Ring Seal

 

 

 

TB

Terminal Block

 

 

 

2