3.Thearrowwillbepointingto"occ"onthescreenToset.

theoccperiodstarttime,pressthesoftbuttonunderthe hourorminuteindictorandthenpresstheupordown buttonschangethetime.

4.Settheheatingtemperaturesetpointforthattimeperiod bypressingthesoftbuttonundertheheatsetpointtem- peraturePresstheupordownbuttonsuntilthedesired. heatingtemperatureisshown.

5.Setthecoolingtemperaturesetpointforthatthneperiod bypressingthesoftbuttonunderthecoolsetpointtem- peraturePresstheupordownbuttonsuntilthedesired. coolingtemperatureisshown.

6.Repeatthisprocessforeachofthethreeremainingtime periods(occ2,occ3,andunocc)byfirstpressingthesoft buttonunderthetimeperiodtoselectit withthearrow. Thenusethesoftkeystochangethestarttime,theheat- ingsetpoint,andthecoolingsetpoint.

7.Pressthedonebuttonwhencomplete.

8.Closethethermostatdoor.

Tosetupaschedulewherealldaysoftheweekwillnotfol- lowthesameschedule,performthefollowing:

1.Fillin Table2 withthedesiredthnesandsetpointsfor eachdayUsethistableasaguideduringprogralmning. andforfuturereference.

2.Open the thermostat door.

3.Press the set button until the screen displays "daily sched- ule" in the center of the screen. The list of the days of the week are displayed on the left.

4.There will be arrows next to each day. This indicates that all seven days will be progralmned the same way. Press the soft button under the days of the week until the arrow is next to the day that will be progralmned.

5.The arrow will be pointing to "occ" on the screen. To set the occ period start time, press the soft button under the hour or minute indicator and then press the up or down buttons to change the time.

6.Set the heating temperature set point for that time period by pressing the soft button under the heat set point tem- perature. Press the up or down buttons until the desired heating temperature is shown.

7.Set the cooling temperature set point for that thne period by pressing the soft button under the cool set point tem- perature. Press the up or down buttons until the desired cooling temperature is shown.

8.Repeat this process for each of the three remaining time periods (occ2, occ3, and unocc) by first pressing the soft button under the time period to select it with the arrow.

Then use the soft keys to change the start thne, the heat- ing set point, and the cooling set point.

9.Press the soft button under the days of the week until the arrow is pointing to the next day that will be pro- gralmned.

10.Repeat Steps 5 to 8 to program the current day.

11.Repeat this process until all the days have been pro- gralmned.

12.Press the done button when complete.

13.Close the thermostat door.

Programming a Holiday Schedule E The user can program a special heating and cooling schedule to follow during holidays or extended absences. To program the holiday schedule, perform the following:

1.Open the thermostat door.

2.Press the set button until the screen displays the holiday settings.

3.Set the heating temperature set point for the holiday by pressing the soft button under the heat set point tempera- ture. Press the up or down buttons until the desired heat- ing temperature is shown.

4.Set the cooling temperature set point for the holiday by pressing the soft button under the cool set point tempera- ture. Press the up or down buttons until the desired cool- ing temperature is shown.

5.Set the humidity set point for the holiday by pressing the soft button under the humidify icon. Press the up or down buttons until the desired humidity is shown.

NOTE: A humidify icon will only be shown for 33CS2PPRH thermostats.

6.Set the mode for the thermostat during the holiday by pressing the mode button. Press the mode button until the arrow is pointing to the desired mode.

7.Press the done button when complete.

8.Close the thermostat door.

Activating the Holiday Program E The user must schedule a return date to activate the holiday settings before

leaving. The thermostat will begin following the holiday schedule after the return date has been selected. On 12:00 AM

of the return date, the thermostat will automatically switch to the progralr_ned schedule.

To activate the holiday program, perform the following:

1.Press the schedule button until the arrow is next to "holi- day."

2.The next day's date will be displayed at the bottom of the screen under the words "return on." There will be a box

Table 2 --Daily Schedule Planner

DAY

 

 

 

SCHEDULE

 

 

 

 

OF THE

 

Occ

 

Occ2

 

 

Occ3

 

Unocc

WEEK

Start Time / Heat / Cool

Start Time / Heat / Cool

Start

Time / Heat / Cool

Start Time / Heat / Cool

Monday

/

/

/

/

 

/

/

/

/

Tuesday

/

/

/

/

 

/

/

/

/

Wednesday

/

/

/

/

 

/

/

/

/

Thursday

/

/

/

/

 

/

/

/

/

Friday

/

/

/

/

 

/

/

/

/

Saturday

/

/

/

/

 

/

/

/

/

Sunday

/

/

/

/

 

/

/

/

/

NOTE: The cooling temperature set point must be higher than the heating temperature set point, (The temperature difference may be changed in the advanced set up configuration by the installer,)

Page 3
Image 3
Carrier 33CS ThearrowwillbepointingtoocconthescreenToset, Pressthedonebuttonwhencomplete Closethethermostatdoor

33CS specifications

The Carrier 33CS is a cornerstone in modern air conditioning systems, designed to deliver optimal comfort, efficiency, and reliability in diverse residential and commercial applications. This model stands out due to its innovative features and advanced technologies that prioritize user experience and energy savings.

One of the main features of the Carrier 33CS is its variable-speed inverter compressor, which allows for precise temperature control. This technology adjusts the cooling output based on the current demand, ensuring that the system operates at its peak efficiency. As a result, the unit not only maintains a consistent indoor climate but also minimizes energy consumption, leading to significant cost savings on utility bills.

The Carrier 33CS is equipped with a high SEER (Seasonal Energy Efficiency Ratio) rating, reflecting its exceptional energy efficiency. This rating makes the unit an environmentally friendly choice, aligning with modern standards for reducing carbon footprints. With its eco-friendly refrigerant, the model also meets stringent regulations, making it suitable for environmentally conscious consumers.

Durability is another hallmark of the Carrier 33CS. Constructed from robust materials, the system is designed to withstand harsh weather conditions, ensuring long-term performance. Additionally, the unit features a corrosion-resistant cabinet that extends its lifespan and maintains its aesthetic appeal over time.

User-friendly controls are integral to the Carrier 33CS. The system often comes with a programmable thermostat that allows users to set schedules and preferences, ensuring that the space is always at the desired temperature. Many models also offer smart connectivity, enabling users to manage their home climate remotely via smartphones or other smart devices.

Quiet operation is another significant advantage of the Carrier 33CS. The advanced design and insulation reduce noise levels, making it an ideal choice for both residential and commercial settings, where disturbances can be problematic.

In summary, the Carrier 33CS embodies a fusion of technology, efficiency, and comfort. With its variable-speed inverter compressor, high SEER rating, durable construction, user-friendly controls, and quiet operation, it remains a leading choice for those seeking a reliable air conditioning solution. Whether in a home or business setting, the 33CS is built to meet the cooling needs of any environment while promoting energy savings and user satisfaction.