MAINTAINING YOUR UNIT

Air Filter(s)

48PD, 48PG

All maintenance should be handled by skilled, experienced personnel. Your dealer can help you establish a standard procedure.

For your safety, keep the area around the unit clear and free of combustible materials, gasoline and other flammable liquids and vapors.

To assure proper functioning of the unit, flow of combustion and ventilating air must not be obstructed from reaching the unit. Clearance of at least 6 ft on all sides is required.

ROUTINE MAINTENANCE AND CARE

FOR THE EQUIPMENT OWNER

Before proceeding with those things you might want to maintain yourself, please carefully consider the following:

!WARNING

FIRE, EXPLOSION HAZARD

Failure to follow this warning could result in personal injury, death, and/or property damage.

1.Turn off gas supply and electrical power to your unit before servicing or performing maintenance.

2.Do not turn off electrical power to this unit without first turning off gas supply and applying lockout tags.

3.When removing access doors or performing maintenance functions inside your unit, be aware of sharp sheet metal parts and screws. Although special care has been taken to reduce sharp edges to a minimum, be extremely careful when handling parts or reaching into the unit.

Air filters should be checked at least every 3 or 4 weeks and changed or cleaned whenever they become dirty. Table 1 indicates the correct filter size for your unit. Open the filter access panel to replace or inspect the filters. All units have filter tracks into which the filters slide. Remove the filters by pulling the filter slide outward from the track. See Fig. 6 for filter access panel location. Note the direction of flow arrows on the filter frame.

If you have difficulty in locating your air filter in the return-air duct system, or if you have questions concerning proper filter maintenance, contact your dealer for instructions. When replacing your unit filters, always use the correct size and quantity as shown in Table 1. Filter tracks are field convertible for 2 or 4-in. thick filters. Verify airflow and duct static values, and related motor sizing and belt drive adjustment, if filter type or efficiency rating is changed from the original installation.

Units with outdoor air capability have cleanable screens for the outdoor air. These screens should be checked annually and cleaned as necessary.

!WARNING

FIRE AND EQUIPMENT DAMAGE HAZARD

Failure to follow this warning could result in personal injury, death, and/or property damage.

Never operate unit without filters in place. Damage to blower motor and/or compressors could result. An accumulation of dust and lint on internal parts of your unit can cause loss of efficiency and in some cases, fire.

9

Page 9
Image 9
Carrier 06 Maintaining Your Unit, Routine Maintenance and Care For the Equipment Owner, Fire and Equipment Damage Hazard

48PD05, 06 specifications

The Carrier 48PD05 and 48PD06 are highly efficient packaged rooftop units designed specifically for commercial applications. They are known for their reliability, advanced technologies, and exceptional performance in diverse weather conditions. Both units leverage Carrier's decades of experience in HVAC technology to deliver optimal indoor comfort with minimal energy consumption.

One of the standout features of the 48PD series is their advanced cooling capabilities. These units utilize scroll compressors, which are renowned for their efficiency and quiet operation. This results in reduced noise levels, making them suitable for a variety of commercial environments, including restaurants, offices, and retail spaces. The units also come equipped with multiple cooling capacities, allowing for precise matching to the specific thermal requirements of the building.

Energy efficiency is a key characteristic of the 48PD05 and 48PD06. Both units feature high SEER (Seasonal Energy Efficiency Ratio) ratings, ensuring that they consume less electricity while delivering superior cooling performance. The use of microchannel coil technology further enhances efficiency. This innovation reduces refrigerant charge requirements and improves heat transfer, allowing the units to operate effectively in various climatic conditions.

In addition to cooling, these units also provide heating functionality, making them an all-in-one solution for year-round climate control. They incorporate electric heating elements as well as optional gas heat capabilities, providing flexibility based on user preference and fuel availability. This versatility ensures that facilities can maintain comfort regardless of seasonal changes.

The Carrier 48PD series is also designed with ease of installation and maintenance in mind. The compact rooftop design allows for straightforward placement on a building’s roof, reducing installation costs and time. Furthermore, serviceability is enhanced through features like removable access panels, which provide easy access to critical components.

Safety and reliability are paramount in Carrier's design philosophy. Both units include a variety of safety features such as high-pressure and low-pressure switches, ensuring the longevity and protection of the system. Additionally, the intelligent controls available with the 48PD models facilitate precise temperature management, enhancing occupant comfort while optimizing energy use.

In conclusion, the Carrier 48PD05 and 48PD06 packaged rooftop units stand out due to their efficient cooling and heating capabilities, innovative technologies, and user-friendly design. Their combination of performance, energy efficiency, and advanced features makes them a reliable choice for commercial heating and cooling needs, assuring users of comfort and cost-effectiveness throughout their operation.