Carrier 58MVC owner manual Replace Blower Access Panel

Models: 58MVC

1 14
Download 14 pages 44.72 Kb
Page 10
Image 10
Fig. 29 - Replace Blower Access Panel

A93205

Fig. 29 - Replace Blower Access Panel

A05100

Fig. 30 - Furnace Door Replaced

A06192

Fig. 31 - Replace Side Filter Cabinet Door

5.If washable filter, wash filter (if dirty) in sink, bathtub, or outside with a garden hose. Always use cold tap water. A mild liquid detergent may be used if necessary. Spray water

through filter in the opposite direction of airflow. Allow filter to dry.

6.Reinstall clean air filter.

7.Reinstall filter retainer (for blower compartment locations only).

8.Replace blower access panel and main furnace door (Fig. 29 and 30.) or filter cabinet door. (Fig. 31 and 32.)

9.Turn on electrical supply to furnace.

If your furnace air filter needs to be replaced, be sure to use a

factory-authorized filter of the same size that was originally

supplied. Use the filter tables and compare your furnace size with the proper filter size.

 

 

 

 

 

 

 

 

 

A06193

 

Fig.

32 - Replace

Bottom Filter Cabinet Door

 

 

FURNACE

AIR

FILTER

TABLE

 

 

AIR FILTER LOCATED IN BLOWER COMPARTMENT

 

FURNACE

 

 

FILTER SIZE - IN (mm)

 

 

CASING

 

 

 

FILTER

 

 

 

 

 

 

 

WIDTH

Side

Return1-*

Bottom Return*

TYPE

IN (mm)

 

 

 

 

 

 

 

 

 

17

1/2

(1)

16X25X3/4

(1) 16X25X3/4

Washable

(445)

(406

 

X 635

X 19)

(406

X 635

X 19)

 

21 (533)

(1)

16X25X3/4

1) 20

X 25 X 3/4

Washable

 

 

(406

 

X 635

X 19)

(508

X 635

X 19)

 

24

1/2

(1or2)

16X25X

(1) 24 X 25

X 3/4

Washable

 

 

 

 

3/4

 

(622)

(406

 

X 635

X 19)

(610

X 635

X 19)

 

 

AIR FILTER LOCATED IN FILTER CABINET

FILTER

CABINET

FILTER

FILTER

HEIGHT

SIZE

TYPE

IN (mm)

IN (mm)

 

16

(406)

(1) 16 x 25 x 3/4"

Washable

 

 

(406 X 635 X 19)

(1)20 x 25 x 3/4"

(508 X 635 X 19)

20

(508)

or

Washable

 

(1) 20

x 25

x 4-5/16

 

(508 X 635 X 11o)

 

(1) 24 x 25 x 3/4"

 

(610 X 635 X 19)

24

(610)

or

Washable

 

(1) 24

x 25

 

x 4-5/16

 

(610 X 635 X 11o)

*Factory-provided with the furnace. Filters may be field modified by cutting filter material and support rods (3) in filters.

1- Upflow only. Alternate sizes and additional filters may be ordered from your dealer.

PERSONAL INJURY HAZARD

Failure to follow this warning could result in personal iniury.

Use care when cutting support rods in filters to protect against flying pieces and sharp rod ends. Wear safety

glasses, gloves, and appropriate protective clothing.

10

Page 10
Image 10
Carrier 58MVC owner manual Replace Blower Access Panel