WASHABLE

FILTER

FILTER

FILTER RETAINER

SUPPORT

A93046

Fig. 3ÐBottom Filter Arrangement

Step 1ÐCleaning and/or Replacing Air Filter

The air filter arrangement may vary depending on the application or orientation.

Never operate unit without a filter or with the blower access panel removed. Failure to follow this warning could result in a fire or personal injury.

To clean or replace the filters, proceed as follows:

1.Turn off electrical supply to furnace.

2.Remove main furnace door and blower access panel.

3.Release filter retainer wire. (See Fig. 3 and 4.)

4.Slide filter out of furnace.

5.Furnaces are equipped with permanent, washable filter(s). Clean filter by spraying cold tap water through filter in opposite direction of airflow.

6.Rinse filter and let dry. Oiling or coating of filter is not recommended.

7.Place filter in furnace.

8.Replace blower access panel and main furnace door.

9.Turn on electrical supply to furnace.

NOTE: If the filter has cross-mesh binding, the binding must face the blower. If the filter has an air direction arrow, the arrow must point toward the blower.

Step 2ÐBlower Motor and Wheel Maintenance

To ensure long life, economy, and high efficiency, clean accumu- lated dirt and grease from blower wheel and motor annually.

The inducer and blower motors are pre-lubricated and require no additional lubrication. These motors can be identified by the absence of oil ports on each end of the motor.

The following items should be performed by a qualified service technician.

Clean blower motor and wheel as follows:

1.Turn off electrical supply to furnace.

2.Remove main furnace door and blower access panel.

3.Disconnect wires.

WASHABLE

FILTER

FILTER

RETAINER

A93045

Fig. 4ÐFilter Installed for Side Inlet

All factory wires can be left connected, but field thermostat connections may need to be disconnected depending on their length and routing.

4.Position control box, transformer, and door switch assembly to right side of furnace casing.

5.If condensate trap is located in left- or right-hand side of furnace casing, proceed to item 6, otherwise remove trap and tubing as described below.

a.Disconnect field drain connection from condensate trap.

b.Disconnect drain and relief port tubes from condensate trap.

c.Remove condensate trap from blower shelf.

6.Remove screws securing blower assembly to blower shelf and slide blower assembly out of furnace.

7.Clean blower wheel and motor by using a vacuum with soft brush attachment. Be careful not to disturb balance weights (clips) on blower wheel vanes. Do not bend wheel or blades as balance will be affected.

8.If greasy residue is present on blower wheel, remove wheel from the blower housing and wash it with an appropriate degreaser. To remove wheel:

a.Mark blower wheel location on shaft before disassembly to ensure proper reassembly.

b.Loosen setscrew holding blower wheel on motor shaft. NOTE: Mark blower mounting arms and blower housing so each arm is positioned at the same hole location during reassembly.

c.Mark blower wheel orientation and cutoff plate location to ensure proper reassembly.

d.Remove screws securing cutoff plate and remove cutoff plate from housing.

e.Remove bolts holding motor mounts to blower housing and slide motor and mounts out of housing. Disconnect capaci- tor and ground wire attached to blower housing before removing motor.

f.Remove blower wheel from housing.

g.Clean wheel per instructions on degreaser cleaner.

9.Reassemble motor and blower wheel by reversing items 8b through 8f. Ensure wheel is positioned for proper rotation. Be sure to reattach ground wire.

10.Reinstall blower assembly in furnace.

3

Page 3
Image 3
Carrier 58MXA instruction manual ÐCleaning and/or Replacing Air Filter, ÐBlower Motor and Wheel Maintenance

58MXA specifications

The Carrier 58MXA is an advanced heating and cooling system that exemplifies Carrier's commitment to innovation, efficiency, and comfort. Designed with the modern homeowner in mind, this gas furnace boasts a range of features that make it stand out in today's market.

One of the primary characteristics of the 58MXA is its impressive efficiency ratings. With AFUE (Annual Fuel Utilization Efficiency) ratings reaching up to 80%, the furnace ensures that homeowners can enjoy warmth during the colder months without excessive energy consumption. This efficiency not only translates to lower utility bills but also contributes to a reduced carbon footprint, making it an eco-friendly choice for environmentally conscious consumers.

The 58MXA utilizes a two-stage heating system which allows for more precise temperature control. This feature enables the furnace to operate at a lower stage for most of the heating cycle, providing comfortable warmth while conserving energy. When temperatures plummet, the system seamlessly switches to a higher stage for added heating capacity, ensuring that homes remain cozy even in extreme cold.

Furthermore, the Carrier 58MXA is engineered with advanced airflow and quiet operation in mind. Its variable-speed blower motor allows for optimal airflow throughout the home, enhancing overall comfort by distributing heat evenly in each room. This system also operates at a significantly reduced sound level compared to standard furnaces, promoting a peaceful indoor environment.

The 58MXA comes equipped with an innovative smart thermostat option, allowing users to monitor and control their home's heating remotely. This capability provides convenience and the opportunity for additional energy savings, as homeowners can adjust settings on the go or set schedules to meet their specific needs.

Durability is another hallmark of the Carrier 58MXA. Constructed with high-quality materials and backed by a manufacturer’s warranty, this furnace is built to withstand the rigors of temperature fluctuations and heavy use. Regular maintenance is also simplified, allowing homeowners to ensure optimal performance over the years.

Overall, the Carrier 58MXA is a top-of-the-line heating solution that combines efficiency, comfort, and advanced technology. Its innovative features and robust design make it an excellent choice for homeowners seeking a reliable and effective heating system. Whether for new construction or upgrading an existing home, the 58MXA is poised to provide years of dependable service.