Carrier instruction manual ÐModel 58PAV Upflow, ÐModel 58RAV Downflow

Models: 58RAV 58PAV

1 12
Download 12 pages 3.08 Kb
Page 4
Image 4
Fig. 6ÐModel 58PAV Upflow

MOUNTING

SCREWS

RELIEFFig. 7ÐModel 58RAV Downflow

BOX

CONTROL

BOARD

FILTER

RETAINER

WASHABLE

FILTER

DRAFT

SAFEGUARD

SWITCH

FLUE

COLLECTOR

BOX

MANUAL

RESET LIMIT

SWITCH

A92063

 

VENT PIPE

 

ENCLOSURE

AUXILIARY

 

LIMIT

 

SWITCH

 

(WHEN USED)

 

MOUNTING

CONTROL

SCREWS

BOARD

 

DRAFT

 

SAFEGUARD

RELIEF

SWITCH

BOX

 

 

MANUAL

 

RESET LIMIT

 

SWITCHES

 

A92064

Fig. 6ÐModel 58PAV Upflow

9.Loosen setscrew holding blower wheel on motor shaft.

10.Remove bolts holding motor mount to blower housing and slide motor and mount out of housing. Disconnect ground wire attached to blower housing before removing motor.

11.Lubricate motor (when oil ports are provided).

a.Remove dust caps or plugs from oil ports located at each end of motor.

b.Use a good grade of SAE 20 nondetergent motor oil and put 1 teaspoon, 5 cc, 3/16 oz, or 16 to 25 drops in each oil port. Do not over-oil.

c.Allow time for total quantity of oil to be absorbed by each bearing.

d.Wipe excess oil from motor housing.

e.Replace dust caps or plugs on oil ports.

12.Remove blower wheel from housing.

a.Mark cutoff location to ensure proper reassembly.

b.Remove screws holding cutoff plate and remove cutoff plate from housing.

c.Lift blower wheel from housing through opening.

13.Clean blower wheel and motor using a vacuum cleaner with soft brush attachment. Do not remove or disturb balance weights (clips) on blower wheel blades. The blower wheel should not be dropped or bent as balance will be affected.

14.Reinstall blower wheel by reversing items 12 a through c. Be sure wheel is positioned for proper rotation.

15.Reassemble motor and blower by reversing items 5 through 10. If motor has ground wire, be sure it is connected as before.

Be sure the motor is properly positioned in the blower housing. The motor oil ports must be at a minimum of 45° above the horizontal centerline of the motor after the blower assembly has been reinstalled in the furnace.

16.Reinstall blower assembly in furnace.

17.Reinstall control. Connect blower electrical leads to control. Please note that the common wire connection is 3/16 in. and all other wire connections are 1/4 in. for assembly. DO NOT FORCE.

Fig. 7ÐModel 58RAV Downflow

18.Reconnect wires to auxiliary limit switch on blower housing (downflow/horizontal furnace only).

19.Reinstall vent pipe and enclosure (downflow/horizontal fur- nace only).

20.Turn on electrical power and check for proper rotation and speed changes between heating and cooling.

21.Replace blower access door. Secure with 2 screws (downflow/horizontal furnace only).

CLEANING HEAT EXCHANGER

The following steps should be performed by a qualified service technician.

NOTE: Deposits of soot and carbon indicate the existence of a problem which needs to be corrected. Take action to correct the problem.

If it becomes necessary to clean the heat exchanger because of carbon deposits, soot, etc., proceed as follows:

1.Turn off gas and electrical power to furnace.

2.Remove 2 screws from front of blower access door (downflow/horizontal furnace only) and remove control and blower access doors.

3.Remove vent pipe enclosure (downflow/horizontal furnace only) and disconnect vent pipe from relief box.

4.Remove 2 screws that secure relief box. (See Fig. 6 or 7.)

5.Disconnect wires to the following components.

a.Draft safeguard switch

b.Inducer motor

c.Pressure switch

d.Limit overtemperature switch(es)

e.Gas valve

f.Hot surface ignitor

g.Flame-sensing electrode

h.Two wiring connectors leading to control

6.Remove 8 screws that secure flue collector box to center panel. Be careful not to damage sealant.

7.Remove complete inducer assembly from furnace, exposing flue openings.

4

Page 4
Image 4