Tank (Sediment) Cleaning
Sediment
tank failure. In some water areas, you may not be able to drain all sediment deposits by simply draining the tank. In
these cases
Sears Service Center. For ordering, refer to the Parts Order List section.
Vent System Inspection
Carbon Monoxide and Fire Hazard
•Flue gases may escape if vent pipe is not connected.
. Be alert for obstructed, sooted or
deteriorated vent system to avoid serious injury or death.
. Do not store corrosive chemicals in vicinity of water heater.
Chemical corrosion of flue and vent
system can cause serious injury or death
Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual.
Burner Inspection
Flood damage to a water heater may not be readily visible or
immediately detectable. However, over a period of time a
flooded water heater will create dangerous conditions which
can cause DEATH, SERIOUS BODILY INJURY, OR
PROPERTY DAMAGE. Contact a Sears Service Center to replace a flooded water heater. Do not attempt to repair the unit! It must be replaced!
At least once a year a visual inspection should be made of the main burner and pilot burner. See Figure 23.
You should check for sooting. Soot is not normal and will impair proper combustion.
Soot
further use. Turn "OFF" gas to water heater and leave off until repairs are made, because failure to correct the cause of the sooting can result in a fire causing death, serious injury, or property damage.
FIGURE 23,
Burner Cleaning
At least once a year a visual inspection should be made of the venting system. You should look for:
Obstructions which could cause improper venting. The
combustion and ventilation air flow must not be obstructed.
Damage or deterioration which could cause improper venting
or leakage of combustion products.
Rusted flakes around top of water heater.
Be sure the vent piping is properly connected to prevent escape
of dangerous flue gasses which could cause deadly asphyxiation.
Obstructions and deteriorated vent systems may present serious health risk or asphyxiation.
Chemical vapor corrosion of the flue and vent system may occur
if air for combustion contains certain chemical vapors. Spray
can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and
sodium chloride, waxes, bleach and process chemicals are typical compounds which are potentially corrosive.
If when inspecting the vent system you find sooting or
deterioration, something is wrong. Call the local gas supplier to correct the problem and clean or replace the flue and venting before resuming operation of the water heater.
Fire or Explosion Hazard
Failure to properly reseal the combustion chamber will disable the flammable vapor ignition resistance feature of this water heater, which could result in death or serious
injury. Contact your local Sears Service Center for assistance.
Read instruction manual before
installing, using or servlcmg
water heater.
In the event your burner needs cleaning, following these instructions:
If inspection of the burner shows that cleaning is required, turn
the gas control knob
The burner needs to be removed for cleaning. Call the Sears Service Center to remove and clean the burner and correct the problem that required the burner to be cleaned.
2O