Removing the Old Water Heater

® ® ®

G

FIGURE 2.

QAttach a hose to the water heater drain valve and put the other end

in a floor drain or outdoors. Open the water heater drain valve. Open a nearby hot water faucet which will relieve pressure in the water heater

and speed draining. The water passing out of the drain valve may be extremely hot. To avoid being scalded, make sure all connections are tight and that the water flow is

directed

away

from any person,

see

Figures

2 and

5.

FIGURE 5,

(_. Disconnect the vent pipe from the draft hood where it connects to the water heater. In most installations the vent pipe can be lifted off after any screw or other attached devices are

removed. Dispose of the draft hood. The new water heater has a draft hood which must be used for proper operation.

QIf you have copper piping to the water heater, the two copper

water pipes can be cut with a hacksaw approximately four inches away from where they connect to the water heater, see Figure 6. This will avoid cutting off pipes too short.

Additional cuts can be made later if necessary. Disconnect

the temperature-pressure relief valve drain line. When the water heater is drained, disconnect the hose from the drain valve. Close the drain valve. The water heater is now

completely disconnected and ready to be removed.

QTurn "OFF" the gas supply to the water heater.

If the main gas line shut-off valve serving all gas appliances is used, also shut "OFF" the gas at each

appliance. Leave all gas

appliances shut "OFF" until the

water heater installation is completed, see Figures 2 and 3.

QTurn "OFF" the water supply to the water heater at the water shut-off

valve or water meter. Some

installations require that the water be turned off to the entire house, see Figures 2 and 4.

FIGURE 3.

FIGURE 4.

FIGURE 6.

If you have galvanized pipes to the water heater, loosen the two galvanized pipes with a pipe wrench at the union in each line. Also disconnect the piping remaining to the water heater, see Figure 7. These pieces should be saved since they may

be needed when reconnecting the new water heater.

Disconnect the temperature-pressure relief valve drain line. When the water heater is drained, disconnect the hose from the drain valve. Close the drain valve. The water heater is

Check again to make sure the gas supply is "OFF" to the water heater. Then disconnect the gas supply connection from

the gas control valve.

,Burn hazard

,Hotwater discharge.

,Keep hands clear of drain valve discharge.

now completely disconnected and ready to be removed.

Mineral buildup or sediment may have accumulated in the old water heater. This causes the water heater to be much

heavier than normal and this residue, if spilled out, could cause staining.

FIGURE 7.

Page 8
Image 8
Kenmore 530, 334 owner manual Removing the Old Water Heater

334, 530 specifications

The Kenmore 334,530 is a well-regarded appliance in the realm of portable air conditioning units, offering users an efficient cooling solution for both homes and office spaces. Known for its reliability and performance, this model blends advanced technology with user-friendly features to create a cooling experience that meets diverse needs.

One of the standout characteristics of the Kenmore 334,530 is its cooling capacity, rated at 14,000 BTU. This makes it suitable for medium to large-sized rooms, effectively cooling spaces up to 600 square feet. Users can expect rapid temperature drops, making it ideal for sweltering summer days when immediate relief is needed.

The unit features a sleek design that allows for easy portability. Equipped with rolling casters, the Kenmore 334,530 can be effortlessly moved from room to room, providing flexibility based on where cooling is needed most. The convenient window installation kit simplifies the setup process, allowing for a straightforward installation without the need for professional assistance.

Energy efficiency is another key highlight of the Kenmore 334,530. With an impressive Energy Efficiency Ratio (EER), this air conditioner is designed to minimize electricity consumption while maintaining powerful cooling performance. Users can stay cool without worrying excessively about their energy bills.

Additionally, the Kenmore 334,530 is equipped with a programmable thermostat and remote control, allowing users to customize their cooling experience. The programmable timer can be set to operate at specific times, ensuring the room is cool when needed while saving energy when it isn't. The user-friendly interface and digital display make adjustments quick and intuitive.

The unit also features multiple fan speeds and cooling modes, including a dehumidifying option that removes excess moisture from the air. This capability not only enhances comfort but contributes to a healthier indoor environment by preventing mold and mildew growth.

In terms of maintenance, the Kenmore 334,530 includes an easy-to-clean washable filter that captures dust and allergens, promoting cleaner air circulation. This filter is designed to be simple to access and maintain, ensuring ongoing efficiency and performance.

Overall, the Kenmore 334,530 stands out in the portable air conditioning market, offering a combination of power, efficiency, and convenience. Its thoughtful features and advanced technology make it an excellent choice for anyone seeking reliable cooling solutions in various settings.