ThankYouforpurchasingKenmorewaterheaterProperly.
installedandmaintained,itshouldgiveyouyearsoftroublefree
serviceIfyoushoulddecidethatyouwantthenewwaterheater.
willarrangeforprompt,qualityinstallationbySearsauthorized
contractors.
AbbreviationsFoundInThis Instruction Manual:
CSA - Canadian Standards Association
ANSI
NFPA - National Fire Protection Association
ASME - American Society of Mechanical Engineers
GAMA - Gas Appliance Manufacturers Association
This
INTERNATIONAL under American National Standard/CSA Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1 (current edition).
Read the "Safety Precautions" section, page 3 of this manual first and then the entire manual carefully. If you don't follow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.
This manual contains instructions for the installation, operation, and maintenance of the
we cannot put everything on the first few pages, READ THE
ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.
The installation must conform with these instructions and the
local code authority having jurisdiction. In the absence of local codes, installations shall comply with the following:
The National Fuel Gas Code ANSI Z223.1/NFPA 54. This
publication is available from the Canadian Standards
Association, 8501 East Pleasant Valley Rd, Cleveland Ohio
44131, or The National Fire Protection Association,
1 Batterymarch Park, Quincy, MA 02269.
If after reading this manual you have any questions or do not
understand any portion of the instructions, call the Sears Service Center.
Carefully plan the place where you are going to put the water
heater. Correct combustion, vent action, and vent pipe
installation are very important in preventing death from
possible carbon monoxide poisoning and fires. See figure 1.
Examine the location to ensure the water heater complies with the Facts to Consider About the Location section in this manual.
For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation
procedures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California Office of the
State Architect, 400 P Street, Sacramento, CA 95814.
Massachusetts Code requires this water heater to be installed
in accordance with Massachusetts
Complies with SCAQMD rule #1121 and districts having equivalent NOx requirements.
|
|
|
|
| RECOVERY | MINIMUM |
| DIMENSIONS | ||
| TANK | TYPE | INPUT | RATE GALS. | VENT PIPE | DIAMETER | IN INCHES (ram) | |||
| CAPACITY | OF | RATE | PER HOUR | INCHES | INCHES | HEIGHT TO | |||
MODEL NUMBER | IN GALS (LTRS) | GAS | (Btu/hr) | @ 90°F RISE | (ram) | (ram) | JACKET TOP | |||
153.334430 | 40 | (151) | NATURAL | 40,000 | 46.9 | 3" (76) or | 4" (102) | 20 I/2" (521) | 55 | I/2" (1,410) |
153.334530 | 50 | (I89) | NATURAL | 40,000 | 45.8 | 3" (76) or | 4" (102) | 22" (558) | 56 | 1/2" (1,435) |