→ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS

The ability to properly perform maintenance on this equip- ment requires certain expertise, mechanical skills, tools, and equipment. If you do not possess these, do not attempt to perform any maintenance on this equipment other than those procedures recommended in the User's Manual. FAILURE TO FOLLOW THIS WARNING COULD RESULT IN POSSIBLE DAMAGE TO THIS EQUIPMENT, SERIOUS PERSONAL INJURY, OR DEATH.

ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS

PROCEDURE

Electrostatic discharge can affect electronic components. Take precautions during furnace installation and servicing to protect the furnace electronic control. Precautions will pre- vent electrostatic discharges from personnel and hand tools which are held during the procedure. These precautions will help to avoid exposing the control to electrostatic discharge by putting the furnace, the control, and the person at the same electrostatic potential.

1.Disconnect all power to the furnace. DO NOT TOUCH THE CONTROL OR ANY WIRE CONNECTED TO THE CON- TROL PRIOR TO DISCHARGING YOUR BODY'S ELEC- TROSTATIC CHARGE TO GROUND.

2.Firmly touch a clean, unpainted, metal surface of the furnace chassis which is close to the control. Tools held in a person's hand during grounding will be satisfactorily discharged.

3.After touching the chassis you may proceed to service the control or connecting wires as long as you do nothing that recharges your body with static electricity (for example; DO NOT move or shuffle your feet, DO NOT touch ungrounded objects, etc.).

4.If you touch ungrounded objects (recharge your body with static electricity), firmly touch furnace again before touching control or wires.

5.Use this procedure for installed and uninstalled (ungrounded) furnaces.

6.Before removing a new control from its container, discharge your body's electrostatic charge to ground to protect the control from damage. If the control is to be installed in a furnace, follow items 1 through 5 before bringing the control or yourself into contact with the furnace. Put all used AND new controls into containers before touching ungrounded objects.

7.An ESD service kit (available from commercial sources) may also be used to prevent ESD damage.

CARE AND MAINTENANCE

For continuing high performance and to minimize possible equip- ment failure, it is essential that periodic maintenance be performed on this equipment. Consult your local dealer as to the proper frequency of maintenance and the availability of a maintenance contract.

Never store anything on, near, or in contact with the furnace, such as:

1.Spray or aerosol cans, rags, brooms, dust mops, vacuum cleaners, or other cleaning tools.

2.Soap powders, bleaches, waxes or other cleaning com- pounds, plastic or plastic containers, gasoline, kerosene, cigarette lighter fluid, dry cleaning fluids, or other volatile fluids.

3.Paint thinners and other painting compounds, paper bags or other paper products.

A failure to follow this warning could result in corrosion of the heat exchanger, fire, personal injury, or death.

Turn off the gas and electrical supplies to the unit before performing any maintenance or service. Follow the operating instructions on label attached to furnace. A failure to follow this warning could result in personal injury.

The minimum maintenance that should be performed on this equipment is as follows:

1.Check and clean air filter each month or more frequently if required. Replace if torn.

2.Check blower motor and wheel for cleanliness each heating and cooling season. Clean and lubricate as necessary.

3.Check electrical connections for tightness and controls for proper operation each heating season. Service as necessary.

As with any mechanical equipment, personal injury can result from sharp metal edges, etc., therefore, be careful when removing parts.

AIR FILTER ARRANGEMENT

The air filter arrangement may vary depending on the application. Refer to Table 1 or 2 for filter size information.

Table 1ÐFilter Size Information for

Downflow/Horizontal Furnaces (In.)

FURNACE

FILTER QUANTITY

FILTER

CASING WIDTH

AND SIZE

TYPE

14-3/16

(2) 14 X 20 X 1

Cleanable

17-1/2

(2) 14 X 20 X 1

Cleanable

21

(2) 16 X 20 X 1

Cleanable

24-1/2

(2) 16 X 20 X 1

Cleanable

Table 2ÐFilter Size Information for

Upflow Furnaces (In.)

FURNACE

FILTER QUANTITY AND SIZE

FILTER

CASING WIDTH

Side Return

Bottom Return

TYPE

14-3/16

(1) 16 X 25 X 1*

(1) 14 X 25 X 1

Cleanable

17-1/2

(1) 16 X 25 X 1*

(1) 16 X 25 X 1

Cleanable

21

(1) 16 X 25 X 1

(1) 20 X 25 X 1*

Cleanable

24-1/2

(2) 16 X 25 X 1*

(1) 24 X 25 X 1

Cleanable

*Factory-provided with the furnace. Filters may be field modified as required by cutting and folding the frame as indicated on the filter.

2

Page 2
Image 2
Carrier 58RAV, 58PAV ÐFilter Size Information for, Downflow/Horizontal Furnaces In, Upflow Furnaces In, Procedure