Section 3 -- Maintenance

Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators

MAINTENENANCE

Figure 3.7 - Setting the Spark Plug Gap

SET PLUG GAP AT 0.76 mm (.030 inch) - 7 kW

0.508 mm (.020 inch) - 12 kW & 15 kW

3.7BATTERY MAINTENANCE

The battery should be inspected per the "Service Schedule," Section 4.1. The following procedure should be followed for inspection:

1.Inspect the battery posts and cables for tightness and corrosion. Tighten and clean as necessary.

2.Check the battery fluid level of unsealed batteries and, if necessary, fill with Distilled Water Only. Do not use tap water in batteries.

3.Have the state of charge and condition checked. This should be done with an automotive-type battery hydrometer.

Wear full eye protection and protective clothing;

Where electrolyte contacts the skin, wash it off immediately with water;

Where electrolyte contacts the eyes, flush thoroughly and immediately with water and seek medical attention; and

Spilled electrolyte is to be washed down with an acid neutralizing agent. A common practice is to use a solution of 1 pound (500 grams) bicarbonate of soda to 1 gallon (4 liters) of water. The bicarbonate of soda solution is to be added until the evidence of reaction (foaming) has ceased. The resulting liquid is to be flushed with water and the area dried.

_ Lead-acid batteries present a risk of fire because they generate hydrogen gas. The

following procedures are to be followed:

DO NOT SMOKE when near the battery;

DO NOT cause flame or spark in battery area; and

Discharge static electricity from body before

touching the battery by first touching a grounded metal surface.

_Be

 

sure the

AUTO/OFF/MANUAL switch is set to

 

the OFF position before connecting the battery

 

cables. If the switch is set to AUTO or MANUAL,

 

the generator can crank and start as soon as

 

the

battery

cables are connected.

 

-A

,A-

_Do

not dispose of the battery

 

in a fire. The

 

battery is capable of exploding.

 

/_

A battery presents a risk of electrical shock

 

and high short circuit current. The following

 

precautions are to be observed when working

 

on batteries:

 

 

Remove the 7.5A and 15A fuses from the

generator control panel.

Remove watches, rings or other metal objects;

Use tools with insulated handles;

Wear rubber gloves and boots;

Do not lay tools or metal parts on top of the battery; and

Disconnect charging source prior to connecting or

disconnecting battery terminals.

_Be

sure the utility power supply is turned off

 

and the 7.5A and 15A fuses are removed from

 

the generator control panel, or sparking may

 

occur at the battery posts as the cables are

 

attached and cause an explosion.

3.8COOLING SYSTEM

Air inlet and outlet openings in the generator compartment must be open and unobstructed for continued proper operation. This includes such obstructions as high grass, weeds, brush, leaves and

snow.

Without sufficient cooling and ventilating air flow, the engine/generator quickly overheats, which causes it to quickly shut down. (See Figure 3.8 for vent locations.)

WARNUNG _°

_Do

_l

not open or mutilate the battery. Released electrolyte has been known to be harmful to

the skin and eyes, and to be toxic.

The electrolyte is a dilute sulfuric acid that is harmful to the skin and eyes. It is electrically

conductive and corrosive. The following procedures are to be observed:

Carrier

1 5

Page 17
Image 17
Carrier ASPASICCA012, ASPASICCA015, ASPASICCA007 owner manual Battery Maintenance, AUTO/OFF/MANUAL switch is set to

ASPASICCA007, ASPASICCA015, ASPASICCA012 specifications

Carrier, a global leader in heating, ventilating, and air conditioning (HVAC) solutions, has consistently made strides in innovation and efficiency with its range of products. Among its notable offerings are the ASPASICCA012, ASPASICCA015, and ASPASICCA007 air conditioning units. These models exemplify cutting-edge technology, designed to meet diverse cooling needs while prioritizing energy efficiency and user comfort.

The ASPASICCA012 model is tailored for small to medium-sized spaces, providing effective cooling with a capacity of 12,000 BTU. This unit is equipped with advanced inverter technology, allowing it to adjust its compressor speed according to the room's cooling requirements. As a result, it operates more efficiently, consuming less energy while maintaining a stable temperature. Additionally, the ASPASICCA012 features a quiet operation design, making it an ideal choice for bedrooms and offices.

For slightly larger areas, the ASPASICCA015 model offers a cooling capacity of 15,000 BTU. It shares similar technological advancements with the ASPASICCA012, including inverter technology and energy efficiency. However, it can handle higher thermal loads, making it suitable for larger living spaces or commercial applications. The ASPASICCA015 also includes user-friendly controls and smart connectivity options, allowing users to operate the unit remotely via mobile apps.

The ASPASICCA007 is another standout model, aimed at providing an energy-efficient solution for compact spaces with a cooling capacity of 7,000 BTU. It utilizes eco-friendly refrigerants, reducing its carbon footprint while ensuring optimal cooling performance. This model emphasizes quiet operation and includes a sleep mode function that gradually adjusts the temperature to enhance comfort during nighttime.

All three models incorporate features such as a programmable timer, multiple fan speeds, and a self-cleaning function to enhance user experience and maintain air quality. Moreover, Carrier’s commitment to sustainability is evident in each unit’s design, which minimizes energy consumption and leverages environmentally friendly refrigerants.

In summary, the Carrier ASPASICCA series, encompassing models 012, 015, and 007, reflects the company’s dedication to innovation, energy efficiency, and user comfort. Whether it’s a small bedroom or a larger commercial space, these air conditioning units provide reliable cooling solutions tailored to a variety of needs while supporting environmental sustainability.