Carrier HRVCCSVB Performing Routine Maintenance, Before You Request A Service Call, Cut Hazard

Models: HRVCCSVB HRVCCSHB

1 4
Download 4 pages 21.39 Kb
Page 3
Image 3
CUT HAZARD

!CAUTION

CUT HAZARD

Failure to follow this caution may result in personal injury.

Although special care has been taken to minimize sharp edges in the construction of your unit, be extremely careful when handling parts or reaching into the unit. Wear appropriate protective clothing and gloves when working on this unit.

PERFORMING ROUTINE MAINTENANCE

1.The motors are factory lubricated. Lubricating the bearings is not recommended.

2.The heat recovery coremust be handled with care. To ensure maximum efficiency of the plastic partitions wash core once a year following the season of most intense use.

Allowthe heat recovery core to soak for 3 hours in a solution ofwarmwater and mild soap. Rinse under a stream ofwarm water. Hot water and strong detergent should NOT be used,as it will damage the heat recovery core.

3.A dirty air filter will cause excessive strain on the blower motor. The filters in your HRV are washable and should be cleaned every 3months.Use a vacuumcleaner to remove the heaviest portion of accumulated dust, then wash in warm water.

The Air Exchange Indicator light on the auto control will indicate when filters should be cleaned. The light will flash on and off until the door is opened to service the unit.

4.Regularly check the screen on the exterior intake hood and clean as necessary.

FRESH AIR

FROM OUTSIDE

STALE AIR

TO OUTSIDE

5.Examine the condensate drain pan to ensure drains are func- tioning properly. Gently clean tray with mild soapy water. (See Fig. 3 and 4).

BEFORE YOU REQUEST A SERVICE

CALL

SCheck the main power disconnect switch. Verify that the circuit breakers are ON or that fuses have not blown. If you must reset breakers or replace fuses, do so only once. Contact your servicing

dealer for assistance if the breakers trip or the fuses blow a second time.

SCheck for sufficient airflow. Check air filters for accumulations of large particles. Check for blocked exhaust-air grilles or ductwork.

Keep grilles and duct work open and unobstructed.

SIf the condensate fails to drain properly, check the grommet and drain tube for obstructions. Make sure that the condensate drain tube has a slight slope and is not kinked.

If your HRV still fails to operate properly, contactyour servicing deal- er. Give him your model and serial number. With this information, the dealer will be able to correct any problems.

Table 1 – Recommended Humidity Levels

OUTSIDE

DOUBLE---PANE

TRIPLE---PANE

TEMPERATURE

WINDOWS

WINDOWS

50°F / 10°C

55%

65%

32°F / 0°C

45%

55%

14°F / --- 10°C

35%

45%

--- 4°F / --- 20°C

30%

45%

--- 22°F / --- 30°C

25%

35%

FRESH AIR

TO BUILDING

STALE AIR

FROM BUILDING

HRV

A92382

Fig. 3 - Vertical Application

3

Page 3
Image 3
Carrier HRVCCSVB Performing Routine Maintenance, Before You Request A Service Call, Cut Hazard, Vertical Application