compression fittings. Plastic compression nut supplied with float valve should not be torqued greater than 25 in.-lb. For copper tubing installations: copper tubing may be connected to float valve by using a field-supplied 1/4 to 1/4 in. straight- through compression union. Run copper tubing to 1 side of compression union and use a standard compression sleeve. Tighten compression nut to torque recommended by manu- facturer. Attach approximately 6 in. of polyethylene supply tubing (supplied) between compression union and float valve. Prepare polyethylene tubing on both ends with brass inserts to prevent tubing collapse. Use compression nut at union to manufacturer's recommended torque, tighten plastic nut on float valve to maximum of 25 in.-lb.

3. Open valve and check installation for leaks.

NOTE: Valve is self piercing on copper lines; 1/4-in. hole must be drilled in steel or iron pipes. Use only a grounded drill or a hand drill to avoid shock hazard. Turn off water and drain the pipe prior to drilling 1/4-in. hole.

Step 8ÐInstall Humidistat and Complete Wiring

1.Mount humidistat on inside wall or return-air duct in accor- dance with section INSTALLATION OF HUMIDISTAT on page 10.

NOTE: Wiring must comply with national electrical code and any local codes or ordinances that may apply. (See Fig. 17.)

HUMIDISTAT

MOTOR

24VAC

FURNACE

 

 

TRANSFORMER

 

HUMIDISTAT

(10-VA)

 

MOTOR

 

115V

24V

FIELD

 

 

WIRING

A96014

Fig.17ÐHumidistat Installation for

HUMCCWTR2019-A--

Step 9ÐStart-Up

1.Open saddle valve to permit water to flow to the solenoid valve.

2.Check all connections for water leaks.

3.Set thermostat to call for heat. Set humidistat at highest humidity setting to be sure the contacts are closed. After a few minutes of operation, check the drain connection for leaks and to see if water is flowing through humidifier.

4.Reverse thermostat and humidistat settings to insure proper shutdown.

5.Reset thermostat to normal setting. Reset humidistat to rec- ommended setting.

Step 10ÐFinal Steps

Attach humidifier maintenance instruction sticker to a visible location.

1.Inform homeowner of proper operation, maintenance, and humidistat setting.

a.If unit is installed during cooling season, close bypass damper, set humidistat for summer setting (OFF or lowest setting).

b. If installed during heating season, set unit for normal operation.

INSTALLATION OF HUMIDISTAT

The humidistat provides automatic control of humidifiers in central heating systems. It is designed for low voltage, wall, or surface duct mounting and contains a SPST snap-acting dustproof switch.

Disconnect power supply before making wiring connections to prevent possible electrical shock and equipment damage. Make wiring connections in accordance with Installation Instruction supplied with the humidifier.

1.Installer must be a trained, experienced service person.

2.Disconnect power supply before beginning installation.

3.Conduct a thorough checkout before leaving installation.

Step 1ÐWall Mounting (Low Voltage)

1.Choose a location for humidistat about 5 ft above floor on inside wall with average room temperature and relative humidity conditions. Maximum ambient temperature of se- lected location must not exceed 125°F. Humidistat may be mounted directly on wall.

2.Drill a small hole in wall and run low-voltage wiring to location chosen. Pull about 6 in. of wire through hole. Plug opening to prevent drafts from affecting humidistat operation.

3.Remove knob, faceplate, and switch assembly from case by following steps listed below.

a.Remove knob by pulling away from casing. (See Fig. 18.)

b.Lift off faceplate, starting at right side. Left end of faceplate protrudes under lip of casing. (See Fig. 18.)

c.Remove switch by removing 2 screws in back of casing. Pressing tab on case. Lift out control. (See Fig. 19.)

MOUNTING HOLES

KNOB

CASE

FACEPLATE

A97102

Fig. 18ÐKnob and Faceplate Removal

4.Make connections to screw terminals on switch assembly. Re-install switch into casing Ð secure with 2 short screws.

10

Page 10
Image 10
Carrier HUMCCLFP1025-A specifications Installation of Humidistat, ÐWall Mounting Low Voltage

HUMCCLFP1025-A specifications

The Carrier HUMCCLFP1025-A is a high-performance air handling unit designed for modern commercial and industrial applications. This model stands out due to its advanced engineering, energy efficiency, and superior air quality management. It addresses the growing demand for effective climate control solutions while ensuring compliance with environmental regulations.

One of the primary features of the HUMCCLFP1025-A is its innovative design, which promotes optimal airflow and temperature regulation. The unit is equipped with a multi-speed fan system that allows for precise adjustments based on the requirements of the space. This flexibility ensures reduced energy consumption while maintaining comfort levels. Additionally, its advanced EC motor technology enhances operational efficiency, leading to significant energy savings over time.

The HUMCCLFP1025-A also incorporates a robust filtering system that captures airborne pollutants, allergens, and particulate matter. The unit utilizes high-efficiency filters, which improve the overall air quality while extending the life of the equipment. The integration of a demand-controlled ventilation system further maximizes efficiency by adjusting the airflow based on occupancy levels, ensuring that only the necessary amount of conditioned air is supplied.

Another noteworthy characteristic of this model is its modular construction. The HUMCCLFP1025-A can be easily customized to meet the specific requirements of various applications. This adaptability allows for easy installation and maintenance, making it a practical choice for building managers and HVAC contractors alike. The unit is designed for quiet operation, minimizing noise disruption in sensitive environments such as offices and healthcare facilities.

Furthermore, the Carrier HUMCCLFP1025-A features advanced connectivity options, including compatibility with Building Management Systems (BMS). This allows for remote monitoring and control, enabling operators to optimize performance and troubleshoot issues in real time. The integration of smart technologies enhances the unit's capabilities, making it a forward-thinking solution in HVAC systems.

In conclusion, the Carrier HUMCCLFP1025-A is a versatile and efficient air handling unit that combines sophisticated design, advanced technology, and superior air quality management. Its range of features, including energy efficiency, customizable configurations, and smart connectivity, make it an ideal choice for various commercial and industrial environments. As the demand for sustainable and effective climate control solutions continues to grow, the HUMCCLFP1025-A stands out as a reliable option that meets the needs of today and the future.