Step 1ÐInspect Package and Check Equipment

Inspect the contents of packaged humidifier. File claim with shipping company prior to installation if shipment is damaged or incomplete.

The package should contain:

1.Humidifier and media assembly

2.Humidistat

3.Template

4.6-in. damper

5.Owner's Manual

6.Warranty Certificate

7.Solenoid valve with bridge rectifier

8.Transfer tube

9.Saddle valve assembly with adapter

10.Three pair of miscellaneous screws

11.Six sheet metal screws

12.Foam tape

13.Water noise reducer (use for water pressure over 60 psi)

14.Worm clamp for field-supplied drain tube

15.Humidifier maintenance instruction sticker

16.Carrier logo label

Step 3ÐPrepare Plenum Opening (See Fig. 2.)

1.Use template for marking humidifier opening.

2.Tape in place on plenum making sure template is level.

IMPORTANT: For humidifier to operate properly it must be level and mounted on a vertical surface.

3. Drill four 1/8-in. holes in plenum.

 

SOLENOID

BROWN

VALVE

ASSEMBLY

"N" COIL

VERTICAL

BYPASS UNITS

ACCESS

DOOR

DRILL (2) HOLES IN DUCT

FOR #8 SHEETMETAL SCREWS

HORIZONTAL

PAD

ACCESS

DOOR

A98368

Fig. 13ÐMounting Solenoid Valve on HUMCCSBP2017-A-- Humidifier

4.Cut opening in plenum using heavy solid lines on template as a guide.

Step 4ÐMount Humidifier

1.Attach foam tape on inside of mounting flange.

2.Determine discharge direction.

3.If right-hand discharge is required:

a.Remove side door and media pad assembly.

b.Invert unit 180 degrees.

c.Re-install media pad and door.

IMPORTANT: Always ensure pad assembly is in the upright position.

4. Attach solenoid valve to unit housing using two screws in

upper mounting holes. (See Fig. 13.) Do not over tighten

screws.

A98367

Fig. 12ÐInstallation of HUMCCSBP2017-A--

Bypass-Type Humidifier

Step 2ÐSelect Location (See Fig. 12.)

Humidifier may be installed on either supply or return plenum. If furnace has air conditioning coil, be sure unit does not interfere with coil ends. Remember to provide clearance for maintenance and evaporator pad removal.

5.

Attach transfer tube to solenoid valve and insert free end into

 

inlet fitting on top of unit housing.

6.

Attach bridge rectifier to solenoid valve.

7.

Insert sheet metal screws into lower holes in plenum, pre-

 

drilled using template.

8.

Tighten screws until heads protrude approximately 3/16-in.

9.

Hang humidifier on bottom screws and push top of humidifier

 

to plenum, aligning top screw holes with flange, and insert

 

screws.

10.

Align and level unit.

11.

Tighten all screws for air tight seal.

7

Page 7
Image 7
Carrier HUMCCLFP1025-A specifications → ÐMounting Solenoid Valve on HUMCCSBP2017-A-- Humidifier, ÐMount Humidifier

HUMCCLFP1025-A specifications

The Carrier HUMCCLFP1025-A is a high-performance air handling unit designed for modern commercial and industrial applications. This model stands out due to its advanced engineering, energy efficiency, and superior air quality management. It addresses the growing demand for effective climate control solutions while ensuring compliance with environmental regulations.

One of the primary features of the HUMCCLFP1025-A is its innovative design, which promotes optimal airflow and temperature regulation. The unit is equipped with a multi-speed fan system that allows for precise adjustments based on the requirements of the space. This flexibility ensures reduced energy consumption while maintaining comfort levels. Additionally, its advanced EC motor technology enhances operational efficiency, leading to significant energy savings over time.

The HUMCCLFP1025-A also incorporates a robust filtering system that captures airborne pollutants, allergens, and particulate matter. The unit utilizes high-efficiency filters, which improve the overall air quality while extending the life of the equipment. The integration of a demand-controlled ventilation system further maximizes efficiency by adjusting the airflow based on occupancy levels, ensuring that only the necessary amount of conditioned air is supplied.

Another noteworthy characteristic of this model is its modular construction. The HUMCCLFP1025-A can be easily customized to meet the specific requirements of various applications. This adaptability allows for easy installation and maintenance, making it a practical choice for building managers and HVAC contractors alike. The unit is designed for quiet operation, minimizing noise disruption in sensitive environments such as offices and healthcare facilities.

Furthermore, the Carrier HUMCCLFP1025-A features advanced connectivity options, including compatibility with Building Management Systems (BMS). This allows for remote monitoring and control, enabling operators to optimize performance and troubleshoot issues in real time. The integration of smart technologies enhances the unit's capabilities, making it a forward-thinking solution in HVAC systems.

In conclusion, the Carrier HUMCCLFP1025-A is a versatile and efficient air handling unit that combines sophisticated design, advanced technology, and superior air quality management. Its range of features, including energy efficiency, customizable configurations, and smart connectivity, make it an ideal choice for various commercial and industrial environments. As the demand for sustainable and effective climate control solutions continues to grow, the HUMCCLFP1025-A stands out as a reliable option that meets the needs of today and the future.