OPTION SWITCHES |
|
| SIDE VIEW |
| |||||||||||||||||||
An internal | COVER REMOVED |
| |||||||||||||||||||||
board may be changed to select various op- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
tions. The cover for the unit must be removed |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
to access the DIP switch. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Accessing Option Switches - The cover is |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
held in place by a |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
the unit. While holding the cover on the sides |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
press hard with your fingers on the back of the | OPTION SWITCHES |
| |||||||||||||||||||||
unit. The chassis will slide out the front. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
Adjusting Option Switches - the DIP Switch is located on |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
| 8 7 6 5 4 3 2 1 |
| |||||||||||||||||||||
the internal PCB assembly board toward the right side of |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
the unit. Switch 1 is toward the back of the unit. Switch | ON |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
‘ON’ position is toward the inside side of the unit. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
| Default Setting Shown |
| ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
.
Siren | ||
|
| with Rotary Selector Switch in Standby |
OFF | OFF | (Default) Produces Horn tone while pressed. |
ON | OFF | Manual control of Mechanical tone. |
|
| Also Mechanical tone continues to fall when Rotary Selector |
|
| Switch is changed from Mechanical Position. |
OFF | ON | Manual control of Wail tone. |
ON | ON | Activates Horn Ring Cycler 2 (HRC2) function. |
HORN RING CYCLER 2 (HRC2) - Turn on DIP
Auxiliary Input Activation Polarity | |||
ON | OFF | OFF | Positive and Negative Activation (Traditional Auxiliary) |
OFF | ON | ON | Positive Only Activation (Factory Default) |
OFF | ON | OFF | Negative Only Activation |
Traditional Auxiliary Input - On earlier models of the
CP5012A | 08/06/08 |