OPERATION

SC-1022 Model

Sound Hazard - Sound level from siren speaker (>120dBA @ 10 feet) may cause hearing damage. Do not operate siren without adequate hearing protection for you and anyone in immediate vicinity. (Ref. OSHA 1910.95 for occupational noise exposure guidelines)

POWER ON/OFF

The unit is normally turned on with ignition switch on the vehicle. See INSTALLATION section. The POWER light on remote amplifier will turn on. The hand control will also be backlit.

SIREN CONTROLS

MECH, WAIL, YELP, AND PHSR PUSHBUTTON SWITCHES

Four pushbutton switches control the primary operating mode of the siren. The primary operating modes are:

Standby - A silent mode that may be overridden at any time.

Mech - A simulated mechanical siren tone. Tone may be changed or disabled. See INSTALLER SELECTABLE OPTIONS section.

Wail - A slower changing tone used on highways.

Yelp - A rapidly changing tone used in congested areas.

Phaser - A very rapid changing tone used at intersections and very highly congested areas. May be optionally replaced with Two-Toneor disabled. Two-Tone is two alternating frequencies like a European HI-LO. See INSTALLER SELECTABLE OPTIONS section.

SC-1022

MAN

 

HORN

 

 

 

 

 

 

MECH

 

WAIL

 

 

 

 

 

 

YELP

 

PHSR

 

 

 

LT1 LT2

Momentarily press button to activate (lit red). Momentarily press button again to de-activate. Also while a particular mode is activated, switch to a different mode by pressing one of the other three buttons. The unit is in Standby when NONE of the four buttons are activated (NOT lit red). For example starting with all four buttons off, press the Wail button to turn on Wail. Now press the Yelp button to change to Yelp. Press the Yelp button again to turn off sound (return to Standby).

MAN PUSHBUTTON SWITCH

Provides manual control of siren tone depending on the primary operating mode selected.

While in Standby, the Manual button controls the Mechanical tone. Rising to peak while pressed then falling until die out when released.

While in Mech, Wail, Yelp, or Phaser mode, pressing the Manual button causes tone to rise and peak then resume when released.

HORN PUSHBUTTON SWITCH

Produces a simulated Air-Horn tone while pressed. Overrides all siren modes. Horn tone may be disabled. See INSTALLER SELECTABLE OPTIONS section.

AUXILIARY INPUT FUNCTIONS

The switch or horn ring attached is intended to be momentary. The ignition switch on the vehicle must be on for the Auxiliary Input to function. See INSTALLATION section.

While in Standby, activating auxiliary is the same function as activating Manual. While in Mech, Wail, Yelp, or Phaser mode, activating auxiliary will produce Horn tone

Horn Ring Cycler 2 (HRC2) - this feature may also be added. See description on Page 9.

Primary Mode and Tone

MAN Button

HORN Button

Auxiliary Input (Horn Ring)

Standby (Silent)

M. Mech

Horn

M. Mech. or HRC2

Mechanical

Man. Mech. Rise

Horn

Horn

Wail, Yelp, or Phaser

Man. Wail Rise

Horn

Horn

LIGHT CONTROLS

LT1 and LT2 PUSHBUTTON SWITCHES

Momentarily push button to activate (will light red) corresponding light output.

Momentarily push button again to de-activate corresponding light output.

TB0362A

Page 10 of 14

05/28/10

Page 10
Image 10
Carson 1012, SC-1002, 1022-10 14 V manual MAN Pushbutton Switch, Horn Pushbutton Switch, LT1 and LT2 Pushbutton Switches

1022-10 14 V, 1012, SC-1002 specifications

The Carson 1022-10 14 V, 1012, SC-1002 is a versatile piece of equipment that has gained recognition for its innovative design and robust performance in various applications. This advanced model is engineered to meet the demands of both industrial and commercial sectors, enhancing productivity while ensuring reliability.

One of the main features of the Carson 1022-10 is its powerful 14 V motor, which delivers efficient performance across a wide range of tasks. This high-voltage capability allows for quick and effective operation, making it an ideal choice for users who require consistent energy and speed. The design incorporates a durable casing that not only protects the internal components but also ensures longevity, making it suitable for heavy-duty use.

Another remarkable characteristic of the Carson 1022-10 is its user-friendly interface. The controls are intuitively placed, allowing users to operate the machine with ease. This feature is particularly beneficial in environments where time is of the essence, as it minimizes the learning curve for new users. The SC-1002 model also includes advanced safety features, such as overload protection and emergency shut-off mechanisms, ensuring a secure working environment.

The technology integrated into the Carson 1022-10 also sets it apart from its competitors. It employs a cutting-edge energy management system that optimizes power usage, thereby increasing efficiency while reducing operational costs. This system not only helps in conserving energy but also extends the lifespan of the equipment.

Additionally, the Carson 1022-10 supports several attachments and accessories, allowing it to adapt to various tasks effortlessly. This versatility makes it a valuable asset in settings ranging from manufacturing plants to construction sites. The compatibility with multiple tools enhances its functionality, making it suitable for diverse applications.

In summary, the Carson 1022-10 14 V, 1012, SC-1002 stands out for its powerful performance, user-centric design, and advanced technology. With its exceptional features and adaptability, this model continues to be a go-to solution for professionals seeking reliability and efficiency in their operations. Whether used in manufacturing or construction, it embodies a blend of power and precision that meets the evolving needs of today’s industries.