SERVICE

This unit is designed to provide years of reliable service under even the worst conditions. Many times there may appear to be a problem with the unit when the true problem is in the speaker(s), controlled devices, or improper installation. The following chart shows typical symptoms and possible causes.

A blown internal siren fuse doesn't necessarily mean that the unit is bad. If a speaker or speaker lead is shorted this fuse will blow before the unit is damaged. Disconnect the SPKR leads and replace the fuse. If the unit itself emits a low level sound when in the Yelp position it is OK. Check the speaker(s) or leads for possible shorting.

PROBLEMS

Symptom

Possible Cause

Check

 

No Power or siren output

Power switch not turned on

Does backlighting come on?

 

 

Bad Speaker

Do you hear a “pop” when turned on?

 

 

Connector or connections loose

With siren on, yelp selected, listen for tone in amplifier.

 

Internal siren fuse blown

Is an external fuse or circuit breaker used?

 

 

Loose connection at power source

Are the power leads connected to a good buss?

No siren tone –

High Voltage Protection

The input voltage must be less than highest rating.

PA works

Mic button stuck

Does mic button release properly?

 

 

Cutout activated

Does siren work when Cutout input is disconnected?

 

Cutout Polarity Option set wrong

Is the CUT P option properly configured?

 

No PA

PA volume not set properly

Try turning the PA volume control.

 

 

Selector in Radio position

PA is not available in the Radio position.

 

Distorted siren sound

Speaker assembly loose

Is the speaker bell or tip loose?

 

 

Intermittent Aux Input connection

Is the Aux Input used and wired properly?

 

 

Low vehicle voltage

The input voltage must be greater than lowest rating.

Intermittent siren tone

High Voltage Protection

Is the vehicle voltage regulator working properly?

 

Connector or connections loose

Is the connector tight on the back of the unit?

 

Loose connection at power source

Check for loose leads back to power source.

 

Mic button activation

Is something lying on the microphone?

 

 

Circuit breaker in supply

Is a circuit breaker used with at least 50A rating?

 

connection

 

 

Horn or Manual or

Horn switch stuck

Does the Horn switch return fully when released?

Phaser stuck on

Man/Phsr switch stuck

Does the Man/Phsr switch return fully when released?

 

Aux Input improperly connected

Is the Aux Input used and wired properly?

 

 

Aux Input Polarity Option set

Is the AUX P option properly configured?

 

 

wrong

 

 

No Radio

Unit not connected to a radio

Is the radio connected properly to the unit?

 

 

Radio volume too low

Can you hear the radio in the vehicle?

 

 

 

Try turning the RAD volume control.

 

Wrong siren tone

Two-Tone option installed.

Is the T-T option jumper cut?

 

 

Aux Input set to wrong function

Is the AUX I option jumper configured properly?

Phaser not working

Phaser disabled

Is the PHSR option jumper cut?

 

Horn not working

Horn disabled

Is the trace cut that disables the Horn switch?

Automatic Siren not

Selector in Radio position

Siren tone is not available in Radio position.

working

Automatic Siren disabled

Is the internal red lead cut from lever switch board?

Automatic Siren in all

No power to red lever switch lead

Do the lever switch relays turn on devices?

 

lever switch positions

 

Check for power at red lever switch lead.

 

 

 

 

 

Lever switch not working

No power to red lever switch lead

Do the lever switch indicators light?

 

in all positions

No ground at siren connector

Check for power at red lever switch lead.

 

Lever switch not working

Loose lever switch output

Does the lever switch indicator light?

 

in some positions

connection on lead

 

 

Lever switch not working

Loose lever switch output

Does the lever switch indicator light?

 

in some positions

connection on lead

 

 

Lever switch output

Internal relay contacts fused from

Is the output current exceeding 20AMPS?

 

stays on

overheating

 

 

Rocker switch outputs

No power to rocker switch

Is the corresponding fuse blown?

 

not working

Loose rocker switch output

Does the rocker switch indicator light turn on?

 

connection on lead

 

 

TB0346A