| Part 4 | USEFUL INFORMATION | 
| 1. | Troubleshooting | 
 | 
 | |
| 
 | Symptom/Problem | Most common causes | Solutions | |
| 
 | 
 | 
 | 
 | |
| 1 | E01 appears on the display. | Changing modes without complet- | Return mode switch to where it stops buzz- | |
| ing transaction. | ing and press p. | |||
| 
 | 
 | |||
| 2 | E08 appears on the display. | Sign on operation is not performed. | Prior to starting registration of any other | |
| 
 | 
 | 
 | operation, press Z~<and then :. | |
| 
 | 
 | 
 | Remove jammed paper. Turn Mode switch | |
| 3 | E94 appears on the display. | Printer paper is jammed. | to OFF then turn to ON, or Turn power OFF | |
| 
 | 
 | 
 | and then turn power ON. | |
| 4 | No date on receipt. | Printer is programmed as a journal. | Program printer to print receipts. | |
| Paper is not advancing enough. | ||||
| 5 | Drawer opens up after ringing up | Department is programmed as a | Program the dept. as a normal dept. | |
| 
 | only one time. | single item dept. | 
 | |
| 6 | Not clearing totals at end of day | Using X mode to take out reports. | Use Z mode to take out reports. | |
| after taking report. | ||||
| 
 | Programming is lost whenever | 
 | 
 | |
| 7 | register is unplugged or there is | Bad or no batteries. | Put in new batteries. | |
| 
 | a power outage. | 
 | 
 | |
| 8 | Register is inoperative. | No power. | Pull lever underneath register at rear. | |
| Can’t get money out of drawer. | ||||
| 9 | E90 appears on the display. | Totals remain in the memory. | Issue the general control reset report, peri- | |
| odic reset report and PLU reset report. | ||||
| 
 | 
 | 
 | 
2.Specifications
INPUT METHODEntry: 
Display (LED): Amount 8 digits (zero suppression); Department/PLU No.; No. of repeats
| PRINTER | 
 | 
| Journal: | 12 digits (Amount 10 digits, Symbol 2 digits) | 
| (or receipt) | Automatic paper roll winding (journal) | 
| Paper roll: | 58 mm ⋅ 80 mm ∅ (Max.) | 
Entry 8 digits; Registration 7 digits; Total 8 digits
CALCULATOR FUNCTION8 digits; Arithmetic calculations; Percent calculations
Memory protection batteries:
The effective service life of the memory protection batteries 3 
Power source/Power consumption: See the rating plate.
Operating temperature: 0°C to 40°C (32°F to 104°F)
| Humidity: | 10 to 90% | 
Dimensions/Weight:188 mm(H)⋅ 330 mm(W)⋅ 360 mm(D) with S drawer 4 kg with S drawer
205 mm(H)⋅ 410 mm(W)⋅ 450 mm(D) with M drawer 8 kg with M drawer
Specifications and design are subject to change without notice.E