Part 4

USEFUL INFORMATION

1.

Troubleshooting

 

 

 

Symptom/Problem

Most common causes

Solutions

 

 

 

 

1

E01 appears on the display.

Changing modes without complet-

Return mode switch to where it stops buzz-

ing transaction.

ing and press p.

 

 

2

E08 appears on the display.

Sign on operation is not performed.

Prior to starting registration of any other

 

 

 

operation, press Z~<and then :.

 

 

 

Remove jammed paper. Turn Mode switch

3

E94 appears on the display.

Printer paper is jammed.

to OFF then turn to ON, or Turn power OFF

 

 

 

and then turn power ON.

4

No date on receipt.

Printer is programmed as a journal.

Program printer to print receipts.

Paper is not advancing enough.

5

Drawer opens up after ringing up

Department is programmed as a

Program the dept. as a normal dept.

 

only one time.

single item dept.

 

6

Not clearing totals at end of day

Using X mode to take out reports.

Use Z mode to take out reports.

after taking report.

 

Programming is lost whenever

 

 

7

register is unplugged or there is

Bad or no batteries.

Put in new batteries.

 

a power outage.

 

 

8

Register is inoperative.

No power.

Pull lever underneath register at rear.

Can’t get money out of drawer.

9

E90 appears on the display.

Totals remain in the memory.

Issue the general control reset report, peri-

odic reset report and PLU reset report.

 

 

 

2.Specifications

INPUT METHOD

Entry: 10-key system; Buffer memory 8 keys (2-key roll over)

Display (LED): Amount 8 digits (zero suppression); Department/PLU No.; No. of repeats

PRINTER

 

Journal:

12 digits (Amount 10 digits, Symbol 2 digits)

(or receipt)

Automatic paper roll winding (journal)

Paper roll:

58 mm 80 mm (Max.)

CALCULATIONS

Entry 8 digits; Registration 7 digits; Total 8 digits

CALCULATOR FUNCTION

8 digits; Arithmetic calculations; Percent calculations

Memory protection batteries:

The effective service life of the memory protection batteries 3 (UM-3, or R6P (SUM-3) type batteries) is approximately one year from installation into the machine.

Power source/Power consumption: See the rating plate.

Operating temperature: 0°C to 40°C (32°F to 104°F)

Humidity:

10 to 90%

Dimensions/Weight:188 mm(H)330 mm(W)360 mm(D) with S drawer 4 kg with S drawer

205 mm(H)410 mm(W)450 mm(D) with M drawer 8 kg with M drawer

Specifications and design are subject to change without notice.

E