Note!
•You can specify an integer in the range of 1 to 9 as the number of partitions, or you can skip input of the number of partitions entirely, if you want.
•Internal integration calculations may take considerable time to complete.
•Display contents are cleared while an integration calculation is being performed internally.
•The conditions described below can cause reduced calculation precision or slower calculation speed.
Condition | Countermeasure |
Minute shifts in the integration | Divide the integration interval, |
interval, which causes large | dividing sections that fluctuate |
change in the integration value | widely into smaller intervals. |
|
|
Periodic functions, or positive and | Separate positive and negative |
negative integration values | parts, and add each together. |
depending on the interval |
|
|
|
Programming a Calculation PRGMRUN | PCL |
|
|
•This section describes how to store a calculation program for instant recall whenever you need it.
•The program storage area has about 360 bytes, which can be divided among up to four different programs named P1, P2, P3, and P4.
•To perform program calculation operations, press F FF, which displays the screen shown below. Next, press the number key that corresponds to the mode you want to select.
PRGM RUN PCL
1 2 3